Table 9 Fabric OS 7.1.0 closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:A race condition between scn processing and name server
triggers a switch panic or host/target access problem in
an AG/NPIV environment.
Take the switches out of AG mode and set them to switch
mode to bring the devices back online.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.Unable to create more than three tunnels with crossport
circuit configuration in a chassis with multiple HP DC SAN
Director Multiprotocol Extension Blades.
Fixed in Fabric OS 7.1.0.Weblinker crashed while adding a host to a crypto target
container using DCFM 10.4.5.
Workaround prior to upgrade:ICL Ports on HP SN8000B 8-Slot SAN Backbone Director/
HP SN8000B 4-Slot SAN Director Switches display
"Mod_Val" on 1 out of 4 ports on a QSFP.
Reseating the QSFP may correct the issue.
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:QSFP port status is not refreshed in the WebTools Port
Admin window. QSFP ICL ports are being fenced due to
Refresh, or close and re-open Port Admin window.
excessive state changes, even though current high threshold
value is not exceeded.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.After an unplug/plug, the HP DC SAN Backbone Director
is running slow even though "top" does not indicate any
tasks taking up time. In addition, all ICLs may take
approximately 10 minutes to come back.
Fixed in Fabric OS 7.1.0.AG details are not present if one AG is incorrectly
registered.
Fixed in Fabric OS 7.1.0.When performing a port disable then enable, the host
will not log back in on 8 Gb/s platforms.
Fixed in Fabric OS 7.1.0.A configured N16 port speed is not displayed as N16 in
the port speed column in the Extended Fabric sub tab on
16 Gb/s platforms.
Fixed in Fabric OS 7.1.0.In an IPSec configuration between HP DC SAN Director
Multiprotocol Extension Blade and an HP 1606 SAN
Extension Switch, some circuits never come online.
Fixed in Fabric OS 7.1.0.Web Tools not working with "IPv6-Only" switches.
Fixed in Fabric OS 7.1.0.In a FICON environment - IEBCOPY job fails during read
pipelining on the HP 1606 SAN Extension Switch / HP
DC SAN Director Multiprotocol Extension Blade.
Fixed in Fabric OS 7.1.0.The HP 8/40 SAN Switch panics if using 8G speed while
running portloopback with loopback cables.
Fixed in Fabric OS 7.1.0.Fabric Watch may not monitor every SNMP event.
Fixed in Fabric OS 7.1.0.Cleanup of crypto stat files fails due to low memory in error
scenarios such as rsync failures.
Fixed in Fabric OS 7.1.0.The HP Encryption SAN Switch does not support HBAs that
send ADISC request before PRLI request.
Fixed in Fabric OS 7.1.0.Manually stopping D-Port tests may result in a software
verify error. The configdownload command fails when
using a user account name with an underscore in it.
Fixed in Fabric OS 7.1.0.The diagshow command displays an incorrect speed value
for ports on FCOE10-24 blades.
Fabric OS 7.1.0 fixes 49