HP B-series Fabric OS 7.1.0c Release Notes (5697-2892, October 2013 - includes all 7.1.0x versions)

Table 9 Fabric OS 7.1.0 closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 7.1.0.A Name Server assert triggered a switch panic.
Fixed in Fabric OS 7.1.0.In a FICON environment, the LPATH Reset flag is not
cleared on local paths if CUB is returned for the first init
IU after a reset - path cannot be assigned as CRP.
Workaround prior to upgrade:One of the E-ports connecting the HP 1606 SAN Extension
Switch and the HP 8/80 Base SAN Switch was segmented
due to (ESC mismatch, Enhanced TI Zone).
portdisable/enable will recover the port.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.Duplicate E_Port SCN from Port error messages are
displayed after an HA Failover.
Fixed in Fabric OS 7.1.0.Remote data replication application fails with multiple paths
(multiple port pairs between arrays) when FastWrite is
enabled on the FCIP tunnel.
Fixed in Fabric OS 7.1.0.A denial of service condition may occur with frequent HTTP
server restarts.
Fixed in Fabric OS 7.1.0.When XISL is disabled in VF, it results in a condition that
can trigger route problem. There may be a loss of
connectivity with large numbers of c3_other_discards.
Workaround prior to upgrade:Out of band bulk requests (SMI) may cause the Name
Server to panic in frame redirection environments.
Avoid GXX_ID (like GCS_ID) queries via out of band
(through RPC) querying with ID of device that is part of
frame redirection.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.FCoE LACP PDU length is non-standard and is discarded.
Fixed in Fabric OS 7.1.0.The RAS log Cx-5021 message for front port partial credit
loss on an EX-Port is not being received.
Fixed in Fabric OS 7.1.0.Unable to access the boot prom on a Brocade 8Gb SAN
Switch for HP BladeSystem c-Class when it is installed in
an embedded server chassis.
Workaround prior to upgrade:Failed tape jobs encountered with tape pipelining enabled
when utilizing a FICON to ESCON converter.
Disable tape pipelining.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.The severity level for SCN-1002 is set to "Error" instead
of "Warning".
Fixed in Fabric OS 7.1.0.Using Web Tools when attempting to upgrade a switch in
IM2/IM3 to Fabric OS 7.0, the fail message should direct
the user to the Interoperability tab to change the switch to
Brocade Native Fabric Mode, but does not.
Fixed in Fabric OS 7.1.0.IPv6(auto) address is not displayed on Web Tools if an
IPv4 address is not configured on a switch.
Fixed in Fabric OS 7.1.0.Replacing a failed HP DC SAN Director Multiprotocol
Extension Blade may result in one circuit on a crossport
configured tunnel getting stuck "In Progress...".
Fixed in Fabric OS 7.1.0.Fabricd crash encountered during D-port testing.
Fixed in Fabric OS 7.1.0.Caution message is displayed when executing D_Port CLI
mentions "only Brocade Branded SFPs", but should not.
Fabric OS 7.1.0 fixes 45