HP B-series Fabric OS 7.1.0c Release Notes (5697-2892, October 2013 - includes all 7.1.0x versions)

1
All ports from a 48 port card must be assigned to a logical switch with zero-based addressing configured. They must
be in a logical switch other than the default switch.
2
Supported only in a logical switch that will not have any FICON traffic. This is for FCP traffic only.
Any blade not listed in Table 8 (page 40) above is not supported in a chassis that carries FICON
traffic.
Fabric OS 7.1.0 fixes
Table 9 (page 41) lists defects closed in the Fabric OS 7.1.0 firmware release.
Table 9 Fabric OS 7.1.0 closed defects
SolutionClosed defect summary
Workaround prior to upgrade:Modifying LUNs while re-key is in progress, will abort the
re-key operation.
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:Inconsistent specification of LUN configuration can result
in multiple paths to the LUN each using different DEKs.
Before enabling the LUN on a Path (Crypto Target
Container) which was disabled, make sure that LUN is not
already enabled on another path (Crypto Target
Container). First delete the LUN that was in disabled state
and add back the LUN to that Crypto Target Container
with the same policies as for the other path of the LUN.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.Switch receives NSd panic when connected to a third-party
switch with interop mode 3 with FOS v6.2.
Fixed in Fabric OS 7.1.0.The sfpshow command displays incorrect information
for static values of XFPs.
Fixed in Fabric OS 7.1.0.The no cee command displays a misleading error
message.
Fixed in Fabric OS 7.1.0.Performing firmware download with diagPost enabled can
lead to unpredictable results, such as continuous CP/BP
reboots or the switch not getting enabled.
Fixed in Fabric OS 7.1.0.The Switch View may not be in synch with the actual
hardware state.
Fixed in Fabric OS 7.1.0.There may be a switch kernel watchdog panic on the HP
8/40 SAN and HP 8/80 SAN Switches with unstable links
or when pulling Ethernet cables.
Fixed in Fabric OS 7.1.0.An "Invalid session" error message displays when
launching Web Tools from DCFM.
Fixed in Fabric OS 7.1.0.The manual rekey all command will not function in a
director-class chassis when multiple EEs are present with
access to the same LUN.
Fixed in Fabric OS 7.1.0.Boot Over SAN fails with switch ports set to 8 Gb on a
Brocade 5470 switch.
Fixed in Fabric OS 7.1.0.Direct P2P FCoE based device logins (VF to VN port) are
being displayed as NPIV logins on the HP 2408 FCoE
Converged Network Switch.
Fixed in Fabric OS 7.1.0.The kacd daemon crashes during offline rekey on REPL
LUNs on the HP Encryption SAN Switch. This results in a
switch reboot and temporary traffic disruption.
Workaround prior to upgrade:Termination of zoned: 13272 was detected when LSAN
zones were pushed from the edge fabric. If multiple scripts
Fabric OS 7.1.0 fixes 41