Brocade Fabric OS Administrator's Guide - Supporting Fabric OS v7.0.1 (53-1002446-01, March 2012)

Fabric OS Administrator’s Guide 191
53-1002446-01
Chapter
9
Installing and Maintaining Firmware
In this chapter
Firmware download process overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191
Preparing for a firmware download . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194
Firmware download on switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196
Firmware download on a Backbone. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
Firmware download from a USB device . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201
FIPS support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202
Test and restore firmware on switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204
Test and restore firmware on Backbones . . . . . . . . . . . . . . . . . . . . . . . . . . 206
Validating a firmware download . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208
Firmware download process overview
Fabric OS v7.0.1 provides nondisruptive firmware installation.
This chapter refers to the following specific types of blades inserted into the Brocade DCX and DCX
8510 Backbone families:
FC blades or port blades that contain only Fibre Channel ports; the Brocade FC10-6 and the
Brocade FC8-16, FC8-32, FC8-48, and FC8-64.
AP blades contain extra processors and specialized ports: Brocade FR4-18i, FA4-18,
FCOE10-24, and FX8-24.
CP blades have a control processor (CP) used to control the entire switch; CP blades can be
inserted only into slots 6 and 7 on the Brocade DCX or DCX 8510-8, and slots 4 and 5 on the
Brocade DCX-4S or DCX 8510-4.
CORE8 and CR4S-8 core blades provide ICL functionality between two Brocade DCX
Backbones. CORE8 blades can be inserted only into slots 5 and 8 on the Brocade DCX. CR4S-8
blades can be inserted only into slots 3 and 6 on the Brocade DCX-4S.
CORE8 and CR4S-8 core blades provide ICL functionality between two Brocade DCX 8510-8
Backbones. CORE8 blades can be inserted only into slots 5 and 8 on the Brocade DCX. CR4S-8
blades can be inserted only into slots 3 and 6 on the Brocade DCX 8510-4.
NOTE
For more information on troubleshooting a firmware download, refer to the Fabric OS
Troubleshooting and Diagnostics Guide.