HP PCIe IO Accelerator for ProLiant Servers
Appendix C: Utilities Reference 38
Internal temperature (avg. and max., since driver load) in degrees Centigrade
Board temperature, in degrees Centigrade
Internal voltage, avg. and max.
Auxiliary voltage:, avg. and max.
Health status: healthy, nearing wearout, write-reduced or read-only
Percentage of good blocks
Basic Information: If no options are used with
fio-status, the following basic
information is reported:
Number and type of boards installed in the system
Attach status
Product name
Product number
Firmware version
Size of the device, out of total capacity
Internal temperature (avg. and max., since driver load) in degrees Centigrade
Health status: healthy, nearing wearout, write-reduced or read-only
Data Volume Information: If the -d option is used, the following basic information is
reported in addition to the basic information:
Physical bytes written
Physical bytes read
Error Mode Information: If the driver is in minimal mode, read-only mode, or write-
reduced mode when fio-status is run, the following differences occur in the output:
Attach status is "Status unknown: Driver is in MINIMAL MODE:"
The reason for the minimal mode state is displayed (such as “Firmware is out of date.
Update firmware.”)
"Geometry and capacity information not available." is displayed.
No media health information is displayed.