HP 3PAR T-Class Installation and Deinstallation Guide

Figure 33 Location of Straps
6. Carefully guide the cabinet down the ramp.
7. Remove the plastic ESD-preventative packing materials from the cabinet and place into the
shipping container for reuse.
NOTE: Retain packing materials, including wooden crates and pallets, for reuse.
Placing the Storage System
After following the guidelines to establish a safe operating site as described in Chapter 1 (page 9),
place the storage system in the operating location.
CAUTION: To avoid tipping the cabinet, use two people to unpack the cabinet. One person
guides the cabinet down the ramp while a second person pushes from behind.
For information on recommended and required access areas, see Section (page 14).
If the operating site has raised floor tiles with cutouts to facilitate cable routing, position the storage
systems over the cutouts in the tiles. See Section (page 14) and Section (page 16) for more
information on the structural considerations involved in using raised flooring.
CAUTION: To avoid potential damage to system equipment, do not adjust the position of the
cabinet when the power is on.
After positioning the cabinet, use the four leveling feet to stabilize the cabinet and prevent movement
during operation.
To stabilize the cabinet with the leveling feet:
Placing the Storage System 45