HP 3PAR T-Class Installation and Deinstallation Guide

Figure 23 Numbering for Fibre Channel Adapters in the Controller Node PCI Slots
Each Fibre Channel adapter in a PCI slot has four ports. Each iSCSI adapter in a PCI slot has two
ports. PCI adapters assume the numbers of the occupying PCI slots.
In dual-port adapters, ports are labeled port 1 and port 2 from top to bottom.
In quad-port Fibre Channel adapters, the ports are numbered port 1, port 2, port 3 and port
4 from top to bottom.
Inside the controller node are control cache DIMMs and data cache DIMMs.
Control cache DIMMs are located in control cache slots 0 and 1 (“Control Cache and Data
Cache DIMMs in the Controller Node (page 35)).
Data cache DIMMs are located on data cache riser cards (“Control Cache and Data Cache
DIMMs in the Controller Node (page 35)).
34 Storage System Physical Layout and Numbering