HP 3PAR T-Class Installation and Deinstallation Guide
d. Choose 1 ==> Configure Node Rescue, then select the desired system.
At this point, you will be prompted for the node rescue configuration information.
1. Verify the current HP 3PAR OS level and enter y to use the level.
2. Enter y to continue to setup node rescue.
NOTE: The process may take a few minutes.
3. Press Enter to accept the default [/dev/tpddev/vvb/0].
4. Enter y to specify the time zone. Continue to follow the time zone setup prompts.
5. Confirm the HP 3PAR OS level and enter y to continue.
5. Choose 2 ==> SP-to-Node Rescue.
NOTE: The process of establishing communication between the SP and StoreServ system
may take several minutes.
6. Establish a serial connection to the node being rescued. If necessary, disconnect the serial
cable from SP.
7. Connect a serial cable from the laptop to the serial port on the node being rescued (S0).
NOTE: Connect the crossover cable to the following ETH port of a specific SP brand:
• HP 3PAR Service Processor DL320e or DL360e: ETH port 2
• Supermicro II: ETH port 1
NOTE: If necessary, check the baud rate settings before establishing a connection.
Service Processor-to-Node Rescue 205