HP 3PAR T-Class Installation and Deinstallation Guide

Service Processor-to-Node Rescue
CAUTION: Before proceeding with the controller node rescue, verify with the system administrator
before disconnecting all host cables or shutting down the host.
NOTE: This SPMAINT node-rescue procedure should only be used if all nodes in the 3PAR system
are down and needs to be rebuilt from the HP 3PAR OS image on Service Processor. The SP-to-node
rescue procedure is supported with HP 3PAR OS version 3.1.2 or higher and HP 3PAR Service
Processor 4.2 or higher.
To perform SP-to-node rescue:
1. At the rear of the storage system, uncoil the red crossover Ethernet cable connected to the SP
(ETH) private network connection and connect this cross-over cable to the E0 port of the node
that is being rescued.
Figure 118 Connecting the Ethernet Cable
NOTE: Connect the crossover cable to the following ETH port of a specific SP brand:
HP 3PAR Service Processor DL320e: ETH port 2
Supermicro II: ETH port 1
2. Connect the maintenance PC to the SP using the serial connection and start an spmaint
session.
3. Go to 3 StoreServ Configuration Management > 1 Display StoreServ information to perform
the pre-rescue task of obtaining the following information:
HP 3PAR OS Level on the StoreServ system
StoreServ system network parameters including netmask and gateway information
Return to the main menu.
NOTE: Copy the network information on to a separate document for reference to complete
the subsequent steps of configuring the system network.
4. In the 3PAR Service Processor Menu, complete the following:
a. Choose 4 ==> StoreServ Product Maintenance.
b. Choose 11 ==> Node Rescue.
c. Enter y to confirm to action before continuing with node rescue.
204 Performing Node Rescue