HP 3PAR T-Class Installation and Deinstallation Guide

10. Press ENTER to accept the default gateway address, or type an alternate default gateway
address and press ENTER. The setup script suggests a default gateway address based on the
supplied IP address.
Please enter the IP address of a default gateway, or NONE [<static.IP.address.1>]:
<default.gateway.address>
11. Type yes to allow inbound and/or outbound files transfers and press ENTER.
Will this ethernet interface be used for inbound and/or
outbound files transfers (yes or no) [no]?
yes
12. Type yes to allow the SP to be remotely controlled and press ENTER.
SP Network Parameters
Enter Control-C at any time to abort this process
Will this SP be allowed to be remotely controlled (yes or no)? [yes]
(Replying 'yes' will allow Remote Operations sessions from a Connection
Server)
[enter]
13. Type m to use the modem for Remote Operations and press ENTER.
SP Network Parameters
Enter Control-C at any time to abort this process
Which media will be used for Remote Operations ( ethernet or modem )?
Enter 'e' or 'm' [modem]:
[enter]
14. Type the phone number, including area code, for the service processor and press ENTER.
SP Network Parameters
Enter Control-C at any time to abort this process
Please enter the SPs local phone number, including area code, using only
the following characters: 0-9 ( ) - , Ex: (510)555-1212 011 813 55 12123:
<splocalnumber>
NOTE: Enter any outside prefix separately, see step 15.
15. Type the prefix required when dialing out from the operating site if applicable and press
ENTER.
SP Network Parameters
Enter Control-C at any time to abort this process
Please enter the required prefixes when dialing out.
- Just hit enter for no prefix
- Number to get an outside line (ex. 8 or 9)
128 Initializing the Storage System Software