HP 3PAR System Reporter 3.1 MU2 Software Release Notes (QL226-97096, April 2014)

DROP TABLE statqos_daily_1;
DROP TABLE statqosinv_hires_1;
DROP TABLE statqosinv_hourly_1;
DROP TABLE statqosinv_daily_1;
4. Upgrade to the SR 3.1 MU2 patch.
NOTE: The purpose of the sysbck tool is to extract System Reporter sampling data from a given
time window for analysis by HP engineers. The sysbck tool is not intended for database migration.
Changes in HP 3PAR System Reporter 3.1 MU2 since version 3.1 MU1
System Reporter now supports:
HP 3PAR OS 3.1.2 MU3 P16, 3.1.1 MU3 P27, and 2.3.1 MU5 P35 patches that have a new
self-signed 2048-bit RSA SSL certificate for HP 3PAR StoreServ Storage.
Increased scalability limit of HP 3PAR InFormOS 3.1.3 for Virtual Volumes and VLUNs.
For more information, see System Reporter Settings in a Highly Scaled Environment section in HP
3PAR System Reporter 3.1 MU2 Software User Guide.
Defects fixed in HP 3PAR System Reporter 3.1 MU2
ResolutionDescription
This issue is fixed by appropriately checking the selection of Use
SSL option.
Whenever sampleloop is started, System Reporter uses
the non-SSL mode for CLI connection to perform a system
check, whether the Use SSL option is selected or not.
Known issues
DescriptionItem
Internet Explorer has a limit of 2048 characters. Firefox (browser) has 65,536
character limit. Apache produces a "413 Entity Too Large" error after 4000 characters.
The message "Unrecognized data
report" can be generated by Internet
Explorer when a URL is very long.
Workaround:
Break the query into a smaller size (especially for PD/LD reports).
Excel 2003 has the row limit set at 65,536. Excel 2007 has a maximum limit of
1,048,576 rows. If the data being retrieved from the database exceeds these limits,
an overflow error occurs.
An overflow message can be
generated by the Build Report Menu
for some reports with a large
Workaround:
No workaround has been found to this problem except filtering the data to run smaller
queries.
number of objects (such as LD
space).
System Reporter requires that the database user in Oracle and MySQL have a
password.
System Reporter does not work
correctly if a database user account
is created without a password.
Workaround:
Ensure that the database user has a password.
The speed of extraction depends on the speed of the database. Also, the current
version of the extraction utility is a single threaded application where the IO speed
depends on the speed of the destination disks.
The extraction utility can take a long
time to perform the extraction
process when working with large
databases.
Workaround:
Extract smaller chunks of data at a time.
Changes in HP 3PAR System Reporter 3.1 MU2 since version 3.1 MU1 5