3PAR Storage Replication Adapter for VMware vCenter Site Recovery Manager 5.0 Implementation Guide

If a failover operation is unsuccessful, make sure to clean up the local disaster state cache.
Otherwise, the subsequent SRM operations will fail.
On both the protected and recovery sites where HP 3PAR SRA is installed, issue the following
command:
tpdsrm viewstate
tpdsrm cleanstate -sysid <StorageSystemID> -rcgroup <RCGroupName>
If HP 3PAR SRA fails the QuerySyncStatus call due the GetTaskStatus call returning the error,
Malformed InServ Data List: xxx, perform the following steps to work around this
problem:
1. Get the task ID from the Malformed InServ Data List: {0 {<TaskID> xxx
error.
2. Log into the HP 3PAR Storage System at the protected site and issue the showtask —d
<TaskID> command. Ensure that the task ID is valid.
3. Issue the removetask —d <TaskID> command to remove the task detail.
4. Re-run the SRM operation again.
If you have multiple failed virtual volumes in the group, you may need to repeat steps 1
through 4 for all volumes.