Cleanup after Failover
The following cleanup is required if a failback is planned between the new protected site (i.e. the
original recovery site) and the new recovery site (i.e. the original protected site) after a failover:
• At the new recovery site (i.e. the original protected site):
◦ Delete failover protection group.
◦ Remove failover virtual machines from the inventory.
◦ Run showvlun command at the new recovery site HP 3PAR Storage System to see the
current LUN exposure and ensure that at least one active LUN is visible (an exposure can
be made to any host). If a LUN is not exposed, you must create at least one LUN via
createvlun command.
◦ Rescan the storage adapters.
Cleanup after Failover 25