HP 3PAR StoreServ 7000/7450 Storage Cabling Configuration Guide E: 4 Node Systems with Large 3.5-inch Drive Enclosures Abstract This guide provides cabling information for authorized technicians performing installation and maintenance services on the HP 3PAR StoreServ 7000/7450 Storage systems.
© Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Acknowledgments Microsoft®, Windows®, are U.S.
Contents 1 Cabling Preparation for HP 3PAR StoreServ 7000/7450.................................5 Following Precautions................................................................................................................5 Identifying and Labeling the Components....................................................................................5 2 Cabling HP 3PAR StoreServ 7000/7450.......................................................8 4 Node 2 Drive Enclosures (2L)..............................
HP 3PAR Documentation..........................................................................................................
1 Cabling Preparation for HP 3PAR StoreServ 7000/7450 The following instructions list important precautions and information about cabling installation options for the storage system.
Types of Components Use the red and green color coding to assist with the cabling. Only connect to components sharing the same color.
Labeling the Enclosures Before connecting the cables: • Labels (A, B, C, and D) are provided to help identify the enclosures in the storage system. Apply the labels to each enclosure in a visible location and avoid covering other labels • Apply label A to the controller enclosure with nodes 0 and 1. Alternate the labeling (A/B) on each enclosure below the controller enclosure If applicable, a system using four nodes, apply label C to the controller enclosure with nodes 2 and 3.
2 Cabling HP 3PAR StoreServ 7000/7450 The following illustrative sections provide a rear view of the rack with recommended racking configuration of the system. 4 Node 2 Drive Enclosures (2L) Before you begin cabling the storage system, carefully read or print the following section, including figures 1 and 2 “Identifying and Labeling the Components” (page 5).
Attach DP-1 Chains to Enclosure This system does not require any connections to node port DP-1.
Attach DP-2 Chains to Enclosures Red routing 1. 2. 3. 4. Connect Connect Connect Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller. all B drive enclosures from (DP-2) to (DP-1) working away from the controller. Node 2 (DP-2) to the I/O 0 (DP-1) on the D drive enclosure closest to the controller. all D drive enclosures from (DP-2) to (DP-1) working away from the controller. Green routing 1. 2. 3. 4.
Review Completed Cabling 4 Node 2 Drive Enclosures (2L) 11
4 Node 4 Drive Enclosures (4L) Before you begin cabling the storage system, carefully read or print the following section, including figures 1 and 2 “Identifying and Labeling the Components” (page 5).
Attach DP-1 Chains to Enclosures Red routing 1. 2. 3. 4. Connect Connect Connect Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller. all A drive enclosures from (DP-2) to (DP-1) working away from the controller. Node 2 (DP-1) to the I/O 0 (DP-1) on the C drive enclosure closest to the controller. all C drive enclosures from (DP-2) to (DP-1) working away from the controller. Green routing 1. 2. 3. 4.
Attach DP-2 Chains to Enclosures Red routing 1. 2. 3. 4. Connect Connect Connect Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller. all B drive enclosures from (DP-2) to (DP-1) working away from the controller. Node 2 (DP-2) to the I/O 0 (DP-1) on the D drive enclosure closest to the controller. all D drive enclosures from (DP-2) to (DP-1) working away from the controller. Green routing 1. 2. 3. 4.
Review Completed Cabling 4 Node 4 Drive Enclosures (4L) 15
4 Node 6 Drive Enclosures (6L) Before you begin cabling the storage system, carefully read or print the following section, including figures 1 and 2 “Identifying and Labeling the Components” (page 5).
Attach DP-1 Chains to Enclosures Red routing 1. 2. 3. 4. Connect Connect Connect Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller. all A drive enclosures from (DP-2) to (DP-1) working away from the controller. Node 2 (DP-1) to the I/O 0 (DP-1) on the C drive enclosure closest to the controller. all C drive enclosures from (DP-2) to (DP-1) working away from the controller. Green routing 1. 2. 3. 4.
Attach DP-2 Chains to Enclosures Red routing 1. 2. 3. 4. Connect Connect Connect Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller. all B drive enclosures from (DP-2) to (DP-1) working away from the controller. Node 2 (DP-2) to the I/O 0 (DP-1) on the D drive enclosure closest to the controller. all D drive enclosures from (DP-2) to (DP-1) working away from the controller. Green routing 1. 2. 3. 4.
Review Completed Cabling 4 Node 6 Drive Enclosures (6L) 19
4 Node Interconnect Cabling The interconnection between Controller A (node pair 0/1), and Controller B (node pair 2/3) uses the four large interconnect cables. The cables are DIRECTIONAL and must be installed correctly for the system to function properly. Connect one cable at a time: 1. Controller A, Node 0, Intr 0 to Controller C, Node 2, Intr 1 2. Controller A, Node 0, Intr 1 to Controller C, Node 3, Intr 0 3. Controller A, Node 1, Intr 0 to Controller C, Node 3, Intr 1 4.
4 Node 8 Drive Enclosures (8L) Before you begin cabling the storage system, carefully read or print the following section, including figures 1 and 2 “Identifying and Labeling the Components” (page 5).
Attach DP-1 Chains to Enclosures Red routing 1. 2. 3. 4. Connect Connect Connect Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller. all A drive enclosures from (DP-2) to (DP-1) working away from the controller. Node 2 (DP-1) to the I/O 0 (DP-1) on the C drive enclosure closest to the controller. all C drive enclosures from (DP-2) to (DP-1) working away from the controller. Green routing 1. 2. 3. 4.
Attach DP-2 Chains to Enclosures Red routing 1. 2. 3. 4. Connect Connect Connect Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller. all B drive enclosures from (DP-2) to (DP-1) working away from the controller. Node 2 (DP-2) to the I/O 0 (DP-1) on the D drive enclosure closest to the controller. all D drive enclosures from (DP-2) to (DP-1) working away from the controller. Green routing 1. 2. 3. 4.
Review Completed Cabling 24 Cabling HP 3PAR StoreServ 7000/7450
4 Node Interconnect Cabling The interconnection between Controller A (node pair 0/1), and Controller B (node pair 2/3) uses the four large interconnect cables. The cables are DIRECTIONAL and must be installed correctly for the system to function properly. Connect one cable at a time: 1. Controller A, Node 0, Intr 0 to Controller C, Node 2, Intr 1 2. Controller A, Node 0, Intr 1 to Controller C, Node 3, Intr 0 3. Controller A, Node 1, Intr 0 to Controller C, Node 3, Intr 1 4.
4 Node 12 Drive Enclosures (12L) Before you begin cabling the storage system, carefully read or print the following section, including figures 1 and 2 “Identifying and Labeling the Components” (page 5).
Attach DP-1 Chains to Enclosures Red routing 1. 2. Connect Node 2 (DP-1) to the I/O 0 (DP-1) on the C drive enclosure closest to the controller. Connect all C drive enclosures from (DP-2) to (DP-1) working away from the controller. Green routing 1. 2. Connect Node 3 (DP-1) to I/O 1 (DP-1) on the C drive enclosure farthest from the controller. Connect all C drive enclosures from (DP-2) to (DP-1) working toward the controller. NOTE: The two adjacent enclosures are not directly connected.
Attach DP-2 Chains to Enclosures Red routing 1. 2. Connect Node 2 (DP-2) to the I/O 0 (DP-1) on the D drive enclosure closest to the controller. Connect all D drive enclosures from (DP-2) to (DP-1) working away from the controller. Green routing 1. 2. Connect Node 3 (DP-2) to I/O 1 (DP-1) on the D drive enclosure farthest from the controller. Connect all D drive enclosures from (DP-2) to (DP-1) working toward the controller. NOTE: 28 The two adjacent enclosures are not directly connected.
Review Completed Cabling 4 Node 12 Drive Enclosures (12L) 29
4 Node Interconnect Cabling The interconnection between Controller A (node pair 0/1), and Controller B (node pair 2/3) uses the four large interconnect cables. The cables are DIRECTIONAL and must be installed correctly for the system to function properly. Connect one cable at a time: 1. Controller A, Node 0, Intr 0 to Controller C, Node 2, Intr 1 2. Controller A, Node 0, Intr 1 to Controller C, Node 3, Intr 0 3. Controller A, Node 1, Intr 0 to Controller C, Node 3, Intr 1 4.
4 Node 14 Drive Enclosures (14L) Before you begin cabling the storage system, carefully read or print the following section, including figures 1 and 2 “Identifying and Labeling the Components” (page 5).
Attach DP-1 Chains to Enclosures Red routing 1. 2. Connect Node 2 (DP-1) to the I/O 0 (DP-1) on the C drive enclosure closest to the controller. Connect all C drive enclosures from (DP-2) to (DP-1) working away from the controller. Green routing 1. 2. Connect Node 3 (DP-1) to I/O 1 (DP-1) on the C drive enclosure farthest from the controller. Connect all C drive enclosures from (DP-2) to (DP-1) working toward the controller. NOTE: 32 The two adjacent enclosures are not directly connected.
Attach DP-2 Chains to Enclosures Red routing 1. 2. Connect Node 2 (DP-2) to the I/O 0 (DP-1) on the D drive enclosure closest to the controller. Connect all D drive enclosures from (DP-2) to (DP-1) working away from the controller. Green routing 1. 2. Connect Node 3 (DP-2) to I/O 1 (DP-1) on the D drive enclosure farthest from the controller. Connect all D drive enclosures from (DP-2) to (DP-1) working toward the controller. NOTE: The two adjacent enclosures are not directly connected.
Review Completed Cabling 34 Cabling HP 3PAR StoreServ 7000/7450
4 Node Interconnect Cabling The interconnection between Controller A (node pair 0/1), and Controller B (node pair 2/3) uses the four large interconnect cables. The cables are DIRECTIONAL and must be installed correctly for the system to function properly. Connect one cable at a time: 1. Controller A, Node 0, Intr 0 to Controller C, Node 2, Intr 1 2. Controller A, Node 0, Intr 1 to Controller C, Node 3, Intr 0 3. Controller A, Node 1, Intr 0 to Controller C, Node 3, Intr 1 4.
4 Node 16 Drive Enclosures (16L) Before you begin cabling the storage system, carefully read or print the following section, including figures 1 and 2 “Identifying and Labeling the Components” (page 5).
Attach DP-1 Chains to Enclosures Red routing 1. 2. Connect Node 2 (DP-1) to the I/O 0 (DP-1) on the C drive enclosure closest to the controller. Connect all C drive enclosures from (DP-2) to (DP-1) working away from the controller. Green routing 1. 2. Connect Node 3 (DP-1) to I/O 1 (DP-1) on the C drive enclosure farthest from the controller. Connect all C drive enclosures from (DP-2) to (DP-1) working toward the controller. NOTE: The two adjacent enclosures are not directly connected.
Attach DP-1 Chains to Enclosures Between Racks Six meter (6m) cables must be used for connections between racks. Red routing 1. 2. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller. Green routing 1. 2. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.
Attach DP-2 Chains to Enclosures Red routing 1. 2. Connect Node 2 (DP-2) to the I/O 0 (DP-1) on the D drive enclosure closest to the controller. Connect all D drive enclosures from (DP-2) to (DP-1) working away from the controller. Green routing 1. 2. Connect Node 3 (DP-2) to I/O 1 (DP-1) on the D drive enclosure farthest from the controller. Connect all D drive enclosures from (DP-2) to (DP-1) working toward the controller. NOTE: The two adjacent enclosures are not directly connected.
Attach DP-2 Chains to Enclosures Between Racks Six meter (6m) cables must be used for connections between racks. Red routing 1. 2. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller. Green routing 1. 2. Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.
Review Completed Cabling 4 Node 16 Drive Enclosures (16L) 41
Review Completed Cabling Between Racks 42 Cabling HP 3PAR StoreServ 7000/7450
4 Node Interconnect Cabling The interconnection between Controller A (node pair 0/1), and Controller B (node pair 2/3) uses the four large interconnect cables. The cables are DIRECTIONAL and must be installed correctly for the system to function properly. Connect one cable at a time: 1. Controller A, Node 0, Intr 0 to Controller C, Node 2, Intr 1 2. Controller A, Node 0, Intr 1 to Controller C, Node 3, Intr 0 3. Controller A, Node 1, Intr 0 to Controller C, Node 3, Intr 1 4.
4 Node 18 Drive Enclosures (18L) Before you begin cabling the storage system, carefully read or print the following section, including figures 1 and 2 “Identifying and Labeling the Components” (page 5).
Attach DP-1 Chains to Enclosures Red routing 1. 2. Connect Node 2 (DP-1) to the I/O 0 (DP-1) on the C drive enclosure closest to the controller. Connect all C drive enclosures from (DP-2) to (DP-1) working away from the controller. Green routing 1. 2. Connect Node 3 (DP-1) to I/O 1 (DP-1) on the C drive enclosure farthest from the controller. Connect all C drive enclosures from (DP-2) to (DP-1) working toward the controller. NOTE: The two adjacent enclosures are not directly connected.
Attach DP-1 Chains to Enclosures Between Racks Six meter (6m) cables must be used for connections between racks. Red routing 1. 2. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller. Green routing 1. 2. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.
Attach DP-2 Chains to Enclosures Red routing 1. 2. Connect Node 2 (DP-2) to the I/O 0 (DP-1) on the D drive enclosure closest to the controller. Connect all D drive enclosures from (DP-2) to (DP-1) working away from the controller. Green routing 1. 2. Connect Node 3 (DP-2) to I/O 1 (DP-1) on the D drive enclosure farthest from the controller. Connect all D drive enclosures from (DP-2) to (DP-1) working toward the controller. NOTE: The two adjacent enclosures are not directly connected.
Attach DP-2 Chains to Enclosures Between Racks Six meter (6m) cables must be used for connections between racks. Red routing 1. 2. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller. Green routing 1. 2. Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.
Review Completed Cabling 4 Node 18 Drive Enclosures (18L) 49
Review Completed Cabling Between Racks 50 Cabling HP 3PAR StoreServ 7000/7450
4 Node Interconnect Cabling The interconnection between Controller A (node pair 0/1), and Controller B (node pair 2/3) uses the four large interconnect cables. The cables are DIRECTIONAL and must be installed correctly for the system to function properly. Connect one cable at a time: 1. Controller A, Node 0, Intr 0 to Controller C, Node 2, Intr 1 2. Controller A, Node 0, Intr 1 to Controller C, Node 3, Intr 0 3. Controller A, Node 1, Intr 0 to Controller C, Node 3, Intr 1 4.