HP 3PAR F-Class, T-Class, StoreServ 10000 Storage Troubleshooting Guide (QL226-96953, May 2013)

RX Multicast: 0 TX Carrier Errors: 0
RX Compressed: 0 TX Compressed: 0
Node
Displays node conditions that are not optimal.
Checks if node batteries have been tested in the last 30 days.
Checks for offline nodes.
Checks for power supply and battery problems.
Format of Possible Node Exception Messages
Node node:<nodeID> "Node is not online"
Node node:<nodeID> "Power supply <psID> detailed state is <status>
Node node:<nodeID> "Power supply <psID> AC state is <acStatus>"
Node node:<nodeID> "Power supply <psID> DC state is <dcStatus>"
Node node:<nodeID> "Power supply <psID> battery is <batStatus>"
Node node:<nodeID> "Node <nodeID> battery is <batStatus>"
Node node:<priNodeID> "<bat> has not been tested within the last 30 days"
Node node:<nodeID> "Node <nodeID> battery is expired"
Node node:<nodeID> "Power supply <psID> is expired"
Node node:<nodeID> "Fan is <fanID> is <status>"
Node node:<nodeID> "Power supply <psID> fan module <fanID> is <status>"
Node node:<nodeID> "Fan module <fanID> is <status>
Node node:<nodeID> "Detailed State <state>" (degraded or failed)
Suggested Node Action, General
For node error conditions, examine the node and node-component states with commands such as
shownode, shownode -s, shownode -d, showbattery, and showsys -d.
Node Example 1
Component -Identifier- ---------------Description----------------
Node node:0 Power supply 1 detailed state is DC Failed
Node node:0 Power supply 1 DC state is Failed
Node node:1 Power supply 0 detailed state is AC Failed
Node node:1 Power supply 0 AC state is Failed
Node node:1 Power supply 0 DC state is Failed
Node Suggested Action 1
Examine the states of the power supplies with commands such as shownode, shownode -s,
shownode -ps, etc. Turn on or replace the failed power supply.
NOTE: In the example below, the battery state is considered Degraded because the power supply
is Failed; this is normal.
cli% shownode
Control Data Cache
Node --Name--- -State-- Master InCluster ---LED--- Mem(MB) Mem(MB) Available(%)
0 1001356-0 Degraded Yes Yes AmberBlnk 2048 8192 100
1 1001356-1 Degraded No Yes AmberBlnk 2048 8192 100
cli% shownode -s
Node -State-- -Detailed_State-