HP 3PAR VMware ESX Implementation Guide

Figure 25 PCI Slot 1 and Slot 2 Configured for FCoE
5. Save the changes and exit the BIOS.
Figure 26 Exiting the BIOS Utility
Configuring an HP 3PAR StoreServ Storage Port for a FCoE Host
Connection
Setting up an FCoE initiator to FC target, does not require any special configuration on the HP
3PAR StoreServ Storage. The initiator coming from the host adapters through the FCoE Forwarder
switch is treated as another Fibre Channel device connecting to the HP 3PAR StoreServ Storage
ports. The same guidelines described in “Configuring the HP 3PAR StoreServ Storage for Fibre
Channel” (page 8) and “Configuring the Host for a Fibre Channel Connection” (page 37) must
be followed when a server with a host CNA card configured with FCoE is connected to HP 3PAR
StoreServ Storage ports.
When setting up FCoE initiator to FCoE target, the StoreServ ports must be configured for FCoE.
See “Configuring the HP 3PAR StoreServ Storage for FCoE” (page 32), for notes on how to configure
FCoE ports on the StoreServ.
NOTE: For specific configurations that support FCoE CNAs and forwarder switches, see the
appropriate HP 3PAR OS release version on the HP SPOCK website: HP SPOCK
Configuring an HP 3PAR StoreServ Storage Port for a FCoE Host Connection 59