HP 3PAR VMware ESX Implementation Guide
For a more complete description of the HP 3PAR OS Persistent Ports feature, its operation, and a
complete list of required setup and connectivity guidelines, see:
• the HP Technical white paper HP 3PAR StoreServ Persistent Ports (HP document
#F4AA4-4545ENW) on the HP SC website:
HP Support Center
• the HP 3PAR Command Line Interface Administrator’s Manual, “Using Persistent Ports for
Nondisruptive Online Software Upgrades”
This document is available on the HP Storage Information Library :
www.hp.com/go/storage/docs
Fibre Channel over Ethernet
NOTE: For information regarding the Persistent Ports feature for an FCoE initiator to FC target
configuration (FCoE to FC switched), see .
HP 3PAR OS Persistent Ports Setup and Connectivity Guidelines for FCoE
Starting with HP 3PAR OS 3.1.3, the HP 3PAR OS Persistent Ports feature is supported for FCoE
target ports (FCoE end-to-end configurations).
Starting with HP 3PAR OS 3.1.3 software and above, the HP 3PAR OS Persistent Ports feature is
enabled by default for HP 3PAR StoreServ Storage FCoE ports during node-down events.
Follow the specific cabling setup and connectivity guidelines for HP 3PAR OS Persistent Ports to
function properly. Key elements for the HP 3PAR OS Persistent Ports feature setup and connectivity
are:
• HP 3PAR StoreServ Storage FCoE partner ports must be connected to the same FCoE network.
• The same CNA port on host-facing HBAs in the nodes of a node pair must be connected to
the same FCoE network, and preferably to different FCoE switches on the network.
• The FCoE network must support NPIV, and NPIV must be enabled.
36 Configuring the HP 3PAR StoreServ Storage for FCoE