HP 3PAR Upgrade Pre-Planning Guide

NOTE: After upgrading from HP 3PAR OS 3.1.2 MU3 to 3.1.3 MU1, the passive node
hangs during a restart. This was observed with: HP 3PAR OS 3.1.3 MU1 (including patches),
Microsoft Windows Server 2012 R1 Standard Edition and HP Cluster Extension V4.0.
If the boot disk without any clustered disks are presented, the system restarts correctly.
If one of the clustered disks is added, the passive node hangs during the restart.
If the clustered disks are added while the passive nodes are running, both the Device
Manager and Disk Manager hang during a re-scan.
To prevent this issue BEFORE upgrading to 3.1.3 MU1: Run the following command on primary
groups on both arrays.
Example: setrcopygroup pol auto_failover <group_name>
To correct this issue AFTER upgrading to 3.1.3 MU1: For the non-peer persistent group, remove
the following policies:
auto_failover
Example: setrcopygroup pol no_auto_failover <group_name>
path_management
Example: setrcopygroup pol no_path_management <group_name>
HP 3PAR Persistent Ports Feature
HP 3PAR OS Persistent Ports feature allows an HP 3PAR StoreServ Storage FC port to assume the
identity (port IP address) of a failed port while retaining its own identity. Where a given physical
port assumes the identity of its partner port, the assumed port is designated as a persistent port.
Array port failover and failback with HP 3PAR OS Persistent Ports feature is transparent to most
host-based multipathing software, which can keep all of its I/O paths active.
The HP 3PAR OS Persistent Ports feature minimizes I/O disruption during an HP 3PAR StoreServ
Storage online upgrade or node-down event (online upgrade, node restart). Port shutdown or reset
events do not trigger this feature.
NOTE: Use of HP 3PAR OS Persistent Ports feature does not negate the need for properly installed,
configured, and maintained host multipathing software.
For a more complete description of the HP 3PAR OS Persistent Ports feature, its operation, and a
complete list of required setup and connectivity guidelines, see:
The HP Technical white paper HP 3PAR StoreServ Persistent Ports (HP document
#F4AA4-4545ENW)
The HP 3PAR Command Line Interface Administrator’s Manual, “Using Persistent Ports for
Nondisruptive Online Software Upgrades
The appropriate HP 3PAR host OS implementation guide
HP 3PAR manuals are available on the HP Storage Information Library at:
www.hp.com/go/storage/docs
HP 3PAR OS Persona Changes
Use Table 2 (page 10) when migrating directly from HP 3PAR OS 2.2.x to HP 3PAR OS 2.3.1.
The change occurs automatically as part of the online or offline upgrade.
NOTE: VCN is disabled by default on all ports when HP 3PAR StoreServ Storage migration to
HP 3PAR OS 2.3.1 completes.
Host Configuration Guidelines 9