HP 3PAR StoreServ Storage Concepts Guide (OS 3.1.2 MU2) (QR482-96384, June 2013)
In the DC3 drive cage, two FC-ALs, each providing four small form-factor pluggable (SFP) modules
to service the drive cage. Figure 19 (page 66) shows the rear view of a DC3 drive cage.
• FC-AL B has four ports, labeled Port B0 through Port B3, from bottom to top.
• FC-AL A has four ports, labeled Port A0 through Port A3, from top to bottom.
Fibre Channel cables connect the ports in the drive cage to the ports on the controller nodes. Each
cable is labeled to indicate the ports it uses.
Figure 19 DC3 Drive Cage (Rear View)
Table 8 DC4 Drive Cage Components
DescriptionItem
Drive Chassis Power Supply 11
FC-AL Port B02
FC-AL Port B13
FC-AL Port B24
FC-AL Port B35
FC-AL Port A06
FC-AL Port A17
FC-AL Port A28
FC-AL Port A39
Drive Chassis Power Supply 010
FC-AL A11
FC-AL B12
Controller Nodes
System controller nodes use Fibre Channel, Gigabit Ethernet, and iSCSI ports to connect the storage
sever to your network, host computers, storage sever components, and to other systems.
Inside each controller node there are slots for network adapters, control cache DIMMs, and data
cache DIMMs. The number of controller nodes in each system, and the type and number of network
adapters is configurable. The number of controller nodes each system model can accommodate
is summarized in Table 9 (page 67).
66 HP 3PAR Storage System Hardware