HP 3PAR StoreServ 7450 Storage Troubleshooting Guide

Table 8 Controller Node LEDs
IndicatesAppearanceLEDCallout
Node status GoodGreenStatus1
On No cluster
Quick Flashing Boot
Slow Flashing Cluster
Node FRU IndicatorBlueHotplug2
On OK to remove
Off Not OK to remove
Flashing locatenode command has been
issued
Node status FaultAmberFault3
On Fault
Off No fault
Flashing Node in cluster and there is a fault
Ethernet LEDs
The controller node has two built-in Ethernet ports and each includes two LEDs:
Figure 20 Ethernet LEDs
Table 9 Ethernet LEDs
IndicatesAppearanceLEDCallout
On 1 Gbe LinkGreenLink Up
Speed
1
On 100 Mbit LinkAmber
Off No link established or 10 Mbit Link
On No Link activityGreenActivity2
Off No link established
Flashing Link activity
FC Port LEDs
The controller node has two FC ports and each includes two LEDs. The arrow heads shaped LEDs
point to the port they are associated with. The following illustration shows the LEDs associated with
the FC-1 port.
Controller Node and Internal Component LEDs 19