HP 3PAR StoreServ 7450 Storage Installation Guide
Verify the Cabling
The cabling for a factory-integrated storage system is complete. You must plug in the power cords
and install the host and Ethernet cables.
NOTE: In a 7450 four controller nodes system, two cable management brackets have Velcro
straps to hold the cables. You can remove and discard these brackets, but HP recommends saving
them for future use. To remove the cable management brackets, loosen the Torx screws and unlatch
the Velcro straps to free the cabling.
Installing and Removing the Cable Restraint Shipping Brackets
The cable restraint shipping brackets support the connected data cables and connectors during
transport. HP recommends installing the brackets before transporting the system to another location
to prevent damage to the connectors. The brackets are not required if the system is in a stationary
position. Retain and store the brackets if they are not being used.
Installing the Brackets
1. Connect the data cables to the enclosure.
2. Attach the hook and loop straps to the brackets.
3. Align the brackets so they parallel to the edges of the enclosure link connectors (see
Figure 13 (page 19)). Adjust the brackets to the height of the screw holes located on the side
rails.
Figure 13 Aligning the Brackets
Verify the Cabling 19