HP 3PAR OS 3.1.2 MU3 P18 Release Notes (QR482-96630, December 2013)

DescriptionItemIssue
number
A diagnostic command, checkPD diag, can lead to an offset overflow
on 3 TB or 4 TB Nearline drives on HP 3PAR StoreServ 7000 Storage
Diagnostic routine can lead
to an offset overflow on 3 TB
or 4 TB Nearline drives on
96945
systems. This patch addresses an offset overflow and is required for any
HP 3PAR StoreServ 7000
Storage systems.
HP 3PAR StoreServ 7000 Storage system with 3 TB or 4 TB Nearline drives
installed.
On some occasions, issuing multiple admits in a short time frame might
cause failure in completion of admit operations. This is resolved.
On system with Data at Rest
(DAR) encryption enabled,
97155
servicemag might result in
unresponsive system.
The specific drives supported by this patch are:
400 GB (HSSC0400S5xnNMME) drives on F class and T class systems
480 GB (HSSC0480S5xnNMRI) and 920 GB (HSSC0920S5xnNMRI) drives on HP 3PAR
StoreServ 7xxx Storage systems and HP 3PAR StoreServ P10000 Storage systems
2 TB (SMEG2000S5xnN7.2 or SMEG2000S5xnF7.2), and 4 TB (SMEG4000S5xnN7.2 or
SMEG4000S5xnF7.2) drives on HP 3PAR StoreServ 7xxx Storage systems and HP 3PAR
StoreServ P10000 Storage systems
2 TB (SMEG2000S5xnN7.2) drives on F class and T class systems.
3 TB (SMEG3000S5xnN7.2) drives on HP 3PAR StoreServ 7xxx Storage systems
450 GB (SLTN0450S5xnF010) and 900 GB (SLTN0900S5xnF010) drives on HP 3PAR
StoreServ 7xxx Storage systems and HP 3PAR StoreServ P10000 Storage systems
Modifications to the HP 3PAR OS 5