HP 3PAR InForm OS 3.1.1 GA/MU1/MU2/MU3 Release Notes

DescriptionItemBug ID
The format of the Logical Block Provisioning Log Page is updated
to match the definition given in recent drafts of the SBC-3 SCSI
specification.
Update LBP Log Page71873
A new property Domains of String[] type is added to
TPD_StorageSystem that contains a list of all the domains that
the current user can see.
Added Domains property to
TPD_StorageSystem that lists all
domains that can seen by the current
user
72077
A new IPAddress property is added for iSCSI
TPD_StorageHardwareID that denotes the IP address of the iSCSI
host.
Added IPAddress property for iSCSI
StorageHardwareID
72078
A new class TPD_StorageDomainGroup is added to model the
domain set. Also, the capability to specify domain a host belongs
to is added to
nl
Added DomainGroup Class and
Capability to Specify Domain during
Host Creation
72079
TPD_StorageHardwareIDManagementService.CreateStorageHardwareIDCollection.
nl
The host domain can be modified via ModifyInstance of
TPD_StorageHardwareIDCollection.
Two methods are added to
StorageHardwareIDManagementService class:
Added SMI-S support for iSCSI host
CHAP configuration
72081
SetISCSICHAP method allows SMI-S client to set the CHAP
secret of an iSCSI host
RemoveISCSISHAP method allows SMI-S client to remove the
CHAP secret of an iSCSI host.
The earlier firmware gets a trap and dumps core when specific
errors are injected on the cage connection from the HBA to the
Emulex LPe12004 FW issue72127
MBOD cage. New Emulex LPe12004 FW version 2.01.x10
addresses this issue.
Failed login attempts via CLI client or IMC now include the
username in the Authentication Failure message. In addition,
Username of failed login attempts
recorded in the event log.
72209
event debug capabilities via showeventlog -debug are restricted
to super roles and service roles only.
Make sure that flusher speed is adjusted back to 0 when zero
LD tunes and regular region moves happen simultaneously.
Incorrect flusher speed after tuning.72270
The SSL libraries in use on the system are updated.SSL libraries updated72389
Added support for 450GB (SEGLE0450GBFC15K) PDs in DC3
and DC4 cages.
New drive supported72486
In earlier versions of InForm OS running on V400/V800 systems,
the cluster manager can choose to reboot the wrong node when
Correct handling of node-to-node link
hardware errors
72602
hardware errors are detected on a node-to-node link. This issue
is addressed now.
L1 (top level meta data table) could be out of sync while removing
a snap virtual volume of size 2TB or more (size must be an even
Snap removal after node down could
cause cluster restart
72914
number of TBs, for example 2TB, 4TB, 6TB and so on.) after
node-down which causes node-down recovery failure and whole
system goes down. This is addressed in 3.1.1 MU2 by
synchronizing L1 exception table every time a snap is removed.
This addresses the zero detect reserve buffer pool to ensure that
it uses contiguous memory. This is required if the allocation is
done in interrupt context for large buffer areas.
Correct buffer allocation when in
interrupt context.
This issue may cause an InServ outage.
72949
Earlier versions of InForm OS could return mode pages in
response to a request for page code 3Fh (all pages), which were
Correct handling of supported mode
pages
73010
not accessible when requested using their individual mode pages.
This inconsistency is now addressed.
Modifications to the InForm OS 41