HP 3PAR InForm OS 3.1.1 Command Line Interface Reference

1 0 OK OK OK OK OK 100
1 1 NotPresent -- -- -- NotPresent 0
In the example above:
Node. The node ID.
PS. The power supply ID.
PSState. The power supply state. Values are as follows:
--. Cannot determine the state.
OK. The power supply is operating normally.
Failed. The power supply is operating abnormally.
NotPresent. The power supply is missing.
Degraded. There is a fan failure, or the battery state is not OK.
FanState. The power supply fan state. Values are as follows:
--. Cannot determine the state.
OK. The fan is operating normally.
Failed. The fan is operating abnormally.
ACState. The state of the AC power. Values are as follows:
--. Cannot determine the state.
OK. Normal operation.
Failed. Abnormal operation.
DCState. The state of DC power. Values are as follows:
--. Cannot determine the state.
OK. Normal operation.
Failed. Abnormal operation.
BatState. The battery state. Values are as follows:
OK. Normal operation.
--. Cannot determine the state.
Failed. Abnormal operation.
NotPresent. The battery is missing.
MaxLifeLow. The maximum battery life is low.
ChrgLvl. The battery charge level in percentage.
The following example displays the detailed state of the nodes:
cli% shownode -s
Node -State- -Detailed_State-