HP 3PAR InForm OS 3.1.1 Command Line Interface Reference

Degraded. The battery is in degraded state.
Not Present. The battery is missing.
Detailed_State. The detailed state of the battery and can be one of the following:
Not Present. The battery is missing.
Expired. The battery is already expired.
Failed. The battery is operating abnormally.
InvalidFirmware. The battery has invalid firmware.
Unknown. The battery state is unknown.
Undefined. The battery state can not be determined.
NOTES
Battery information is set by issuing the setbattery command. See setbattery” (page 282)
for more information.
For the E-Class and F-Class Storage Servers, the Power Supply 0's primary node is 0 and its
secondary node is 1. The Power Supply 1's primary node is 1 and its secondary node is 0.
The primary node can read and modify the power supply's properties. The secondary node
can only read the power supply's properties. Therefore, for the E-Class and F-Class, with the
-old option, the battery information for Node 0 Power Supply 0 is the same as the battery
information for Node 1 Power Supply 0. The battery information for Node 1 Power Supply
1 is the same as the battery information for Node 0 Power Supply 1.
showbattery 355