HP 3PAR HP-UX Implementation Guide
NOTE: Topology will be PRIVATE_LOOP for a direct connection and PTTOPT_FABRIC for
a fabric connection. The example below is for fabric.
# fcmsutil /dev/fcd2 (for Fabric connect)
Vendor ID is = 0x001077
Device ID is = 0x002422
PCI Sub-system Vendor ID is = 0x00103c
PCI Sub-system ID is = 0x0012df
PCI Mode = PCI-X 133 MHz
ISP Code version = 5.3.2
ISP Chip version = 3
Topology = PTTOPT_FABRIC
Link Speed = 4Gb
Local N_Port_id is = 0x030800
Previous N_Port_id is = None
N_Port Node World Wide Name = 0x500110a0003d9609
N_Port Port World Wide Name = 0x500110a0003d9608
Switch Port World Wide Name = 0x200800c0dd1f3ab3
Switch Node World Wide Name = 0x100000c0dd18f8a4
Driver state = ONLINE
Hardware Path is = 2/0/11/1/0/4/0
Maximum Frame Size = 2048
Driver-Firmware Dump Available = NO
Driver-Firmware Dump Timestamp = N/A
Driver Version = @(#) libfcd.a HP Fibre Channel ISP 23xx & 24xx Driver B.11.23.1205
/ux/core/isu/FCD/kern/src/common/wsio/fcd_init.c:Apr 27 2012,05:18:14
3. The Vital Product Data (VPD), including firmware version (Engineering Data Code), is shown
using the vpd option of fcmsutil for AD194A HBA on the Itanium Server.
# fcmsutil /dev/fcd2 vpd
V I T A L P R O D U C T D A T A
--------- ------------- -------
Product Description : HP PCI-X 2p 4Gb FC AND 2p 1000BT Adptr
Part number : AD194-60001
Engineering Date Code : A-4651
Part Serial number : JP47060179
Misc. Information : PW=15W;PCI=66MHZ;PCI-X=133MHZ
Mfd. Date : 4706
Mfd. ID : AD194-60001
Check Sum : 0x95
EFI version : 02.22
ROM Firmware version : 05.03.15
BIOS version : 02.16
FCODE version : 02.03
Asset Tag : NA
4. Use fcmsutil to find out other command fabric service parameters and connected storage
server port WWNs. Here is an example for a fabric connection:
# fcmsutil /dev/fcd2 get remote all
Target N_Port_id is = 0x030500
Target state = DSM_UNOPENED
Symbolic Name = 3PAR
Setting Up Multipathing Software on HP-UX 11i v2 35