HP 3PAR FalconStor CDP NSS Implementation Guide

Figure 1 HA Cluster of FalconStor CDP/NSS Servers
Configuring Ports for InForm OS 3.1.x
Configure the desired HP 3PAR Storage System server ports as fabric target ports that will connect
to ports designated as initiators on the FalconStor CDP/NSS appliance. In this example, two ports
were configured as fabric targets. For high availability, the ports were located on alternate HP 3PAR
Storage System nodes. Each target was zoned creating two paths with two initiators, residing on
alternate FalconStor CDP/NSS appliances. Configure the fabric ports by issuing the following
InForm OS CLI commands:
cli% control port offline [node:slot:port]
cli% controlport config host -ct point [node:slot:port]
cli% controlport rst [node:slot:port]
Example:
NOTE: The following example applies to F-class and T-class systems, which have MaxRate values
of 4 Gbps. For the P10000 system, the MaxRate value (for both the 0:2:1 host and the 1:4:1 host)
is 8 Gbps.
cli% controlport offline 0:2:1
cli% controlport offline 1:4:1
cli% controlport config host -ct point 0:2:1
8 Configuring the HP 3PAR Storage System and FalconStor CDP/NSS for Fibre Channel