HP 3PAR CIM API Programming Reference
"before the method returns." ),
ModelCorrespondence { "CIM_Synchronized.CopyState" }]
uint16 WaitForCopyState);
[Description (
"Create (or start a job to create) a new group of storage "
"objects which are replicas of the specified source "
"storage or a group of source storage objects "
"(SourceElements). Note that using the input parameter, "
"SyncType, this function can be used to instantiate the "
"replicas, and to create ongoing associations between "
"the source(s) and replicas. If 0 is returned, the "
"function completed successfully and no ConcreteJob "
"instance is created. If 4096/0x1000 is returned, a "
"ConcreteJob is started, references to which is returned "
"in the Jobs output parameter."
"An array of references to StorageSynchronized associations, "
"one for each pair of members in the source and target group, "
"are returned in Synchronizations. GroupSynchronization "
"asociation is not supported." ),
ValueMap { "0", "1", "2", "3", "4", "5", "6", "..", "4096",
"4097..32767", "0x8000.." },
Values { "Completed with No Error", "Not Supported",
"Unknown", "Timeout", "Failed", "Invalid Parameter",
"In Use", "DMTF Reserved",
"Method Parameters Checked - Job Started",
"Method Reserved", "Vendor Specific" }]
uint32 TPD_CreateGroupReplica(
[IN, Description (
"Depricated. "
"Use CreateGroupReplica, CreateGroupReplicaFromElements, "
"or CreateListReplica instead. "
"A user relevant name for the relationship between "
"the source and target groups or between a source "
"element and a target group (i.e. one-to-many). If "
"NULL, the implementation assigns a name. If the "
"individual target elements require an ElementName, "
"the implementation constructs an appropriate "
"ElementName using the RelationshipName. For "
"example, RelationshipName as a prefix followed by "
"\"_n\" sequence number, where n is a number "
"beginning with 1." )]
string RelationshipName,
[Required, IN, Description (
"SyncType describes the type of copy that will be made."
),
ValueMap { "..", "6", "7", "8", "..", "0x8000.." },
Values { "DMTF Reserved", "Mirror", "Snapshot",
"Clone", "DMTF Reserved", "Vendor Specific" },
ModelCorrespondence { "CIM_Synchronized.SyncType" }]
uint16 SyncType,
[IN, Description (
"Mode describes whether the target elements will be "
"updated synchronously or asynchronously. If NULL, "
"implementaton decides the mode." ),
ValueMap { "2", "3", "..", "0x8000.." },
Values { "Synchronous", "Asynchronous",
"DMTF Reserved", "Vendor Specific" },
ModelCorrespondence { "CIM_Synchronized.Mode" }]
uint16 Mode,
[IN, Description (
"A group of source storage objects of StorageVolume." )]
CIM_ReplicationGroup REF SourceGroup,
[IN, Description (
"As an input, refers to a target group "
"to use. This is valid only if SyncType is "
300 Managed Object Format Files