HP 3PAR AIX and IBM Virtual I/O Server Implementation Guide

hostname WWN to add the additional paths to the defined HP 3PAR StoreServ Storage
host definition.
b. On the AIX host CLI, execute the cfgmgr command.
On the IBM Virtual I/O Server host CLI, in the oem_setup_env environment, execute
the cfgmgr command.
c. Verify that all paths appear on the HP 3PAR StoreServ Storage by issuing the following
command.
For the AIX host:
# showhost -h aixhost
For the IBM Virtual I/O Server:
# showhost VIOS
7. To add the additional paths to the boot device configuration, choose one of the following
methods:
Issue /usr/lib/methods/cfgefscsi l fscsiX on the AIX or IBM Virtual I/O
Server CLI, where X is the additional path’s FC SCSI controller protocol device.
# /usr/lib/methods/cfgefscsi -l fscsi1
hdisk0
# /usr/lib/methods/cfgefscsi -l fscsi2
hdisk0
# /usr/lib/methods/cfgefscsi -l fscsi3
hdisk0
OR
Issue cfgmgr vl hdiskX in the AIX or IBM Virtual I/O Server CLI, where X is the HP
3PAR StoreServ Storage volume for the host boot.
# cfgmgr -vl hdisk0
----------------
attempting to configure device 'hdisk0'
Time: 0 LEDS: 0x626
invoking /usr/lib/methods/cfgscsidisk -l hdisk0
Number of running methods: 1
----------------
Completed method for: hdisk0, Elapsed time = 0
return code = 0
****************** no stdout ***********
****************** no stderr ***********
----------------
Time: 0 LEDS: 0x539
Number of running methods: 0
----------------
calling savebase
return code = 0
****************** no stdout ***********
****************** no stderr ***********
Configuration time: 0 seconds
Installing the AIX or IBM Virtual I/O Server Host OS for a SAN Boot 45