HP 3PAR AIX and IBM Virtual I/O Server Implementation Guide
NOTE: HP recommends enabling the 3par_pathmon.sh script that is provided with HP 3PAR
ODM 3.1. This daemon-like program monitors the HP 3PAR device paths that are in a Failed
state. For all paths in a Failed state that the health check function cannot bring back, a chpath
command is issued to enable them. See the README provided with the HP 3PAR ODM 3.1 for
instructions and usage.
Displaying the Path Status After Installing HP 3PAR ODM
After the installation of the HP 3PAR MPIO for AIX HBA, verify that the HP 3PAR ODM has been
installed successfully:
# lslpp -l|grep -i 3par
3PARmpio.64 3.1.0.0 COMMITTED 3PAR Multipath I/O for IBM
After the installation of the ODM for AIX MPIO, check path status and verify the connection between
the host server and HP 3PAR StoreServ Storage.
• To display the FC device available on the AIX or IBM Virtual I/O Server host, issue lsdev
-Cc disk.
# lsdev -Cc disk
hdisk0 Available 00-08-00 SAS Disk Drive
hdisk1 Available 07-00-01 3PAR InServ Virtual Volume
hdisk2 Available 07-00-01 3PAR InServ Virtual Volume
hdisk3 Available 07-00-01 3PAR InServ Virtual Volume
hdisk4 Available 07-00-01 3PAR InServ Virtual Volume
hdisk5 Available 07-00-01 3PAR InServ Virtual Volume
• To display the path status through the AIX CLI on hdisk1, issue lspath –l hdisk1:
# lspath -l hdisk1
Enabled hdisk1 fscsi4
Enabled hdisk1 fscsi4
Enabled hdisk1 fscsi4
Enabled hdisk1 fscsi4
Enabled hdisk1 fscsi4
Enabled hdisk1 fscsi5
Enabled hdisk1 fscsi5
Enabled hdisk1 fscsi5
Enabled hdisk1 fscsi5
Enabled hdisk1 fscsi5
• To display the specific path information on hdisk1, issue lspath -l hdisk1 -F “status
name parent connection”.
NOTE: Highlighted text shows the details for node, slot, and port <n:s:p>.
# lspath -l hdisk1 -F “status name parent connection”
Enabled hdisk1 fscsi4 20510002ac0000b3,0
Enabled hdisk1 fscsi4 20410002ac0000b3,0
Enabled hdisk1 fscsi4 21210002ac0000b3,0
Enabled hdisk1 fscsi4 21410002ac0000b3,0
22 Connecting the Host Server with Fibre Channel