• To display the path status through the AIX CLI on hdisk1, type lspath –l hdisk1:
# lspath -l hdisk1
Enabled hdisk1 fscsi4
Enabled hdisk1 fscsi4
Enabled hdisk1 fscsi4
Enabled hdisk1 fscsi4
Enabled hdisk1 fscsi4
Enabled hdisk1 fscsi5
Enabled hdisk1 fscsi5
Enabled hdisk1 fscsi5
Enabled hdisk1 fscsi5
Enabled hdisk1 fscsi5
• To display the specific path information on hdisk1, type lspath -l hdisk1 -F “status
name parent connection”.
NOTE: Highlighted text shows the details for node, slot, and port <n:s:p>.
# lspath -l hdisk1 -F “status name parent connection”
Enabled hdisk1 fscsi4 20510002ac0000b3,0
Enabled hdisk1 fscsi4 20410002ac0000b3,0
Enabled hdisk1 fscsi4 21210002ac0000b3,0
Enabled hdisk1 fscsi4 21410002ac0000b3,0
Enabled hdisk1 fscsi4 21510002ac0000b3,0
Enabled hdisk1 fscsi5 20510002ac0000b3,0
Enabled hdisk1 fscsi5 20410002ac0000b3,0
Enabled hdisk1 fscsi5 21210002ac0000b3,0
Enabled hdisk1 fscsi5 21410002ac0000b3,0
Enabled hdisk1 fscsi5 21510002ac0000b3,0
• To display the basic path status for ALL MPIO devices, type the lspath command.
# lspath
Enabled hdisk0 sas0
Enabled hdisk1 fscsi4
Enabled hdisk2 fscsi4
Enabled hdisk1 fscsi4
Enabled hdisk2 fscsi4
Enabled hdisk1 fscsi4
Enabled hdisk2 fscsi4
Enabled hdisk1 fscsi4
Enabled hdisk2 fscsi4
Enabled hdisk1 fscsi4
Enabled hdisk2 fscsi4
Enabled hdisk1 fscsi5
Enabled hdisk2 fscsi5
Enabled hdisk1 fscsi5
Enabled hdisk2 fscsi5
Enabled hdisk1 fscsi5
Enabled hdisk2 fscsi5
Enabled hdisk1 fscsi5
Enabled hdisk2 fscsi5
Enabled hdisk1 fscsi5
Enabled hdisk2 fscsi5
20 Connecting the Host Server with Fibre Channel