HP 3PAR 3.1.3 Downgrade Instructions

3 Verification and Preparation
1. Verify that the hardware is compatible with HP 3PAR OS 3.1.2.484 (MU3). If the hardware
is not compatible with HP 3PAR OS 3.1.2.484 (MU3), the downgrade procedure cannot
continue.
2. Run Out of the Box (OOTB) following the normal procedures.
3. Verify that Peer Motion is stopped before downgrading. Refer to the HP 3PAR Peer Motion
Manager User Guide for additional information.
4. If storage system is not added to the SP, then to add the storage system to the SP, enter: =3.2
and press Enter, then follow the instructions from the SP.
5. From the SPMAINT main menu, enter: 7 (Interactive CLI for a StoreServ) and
select the Storage System.
6. To verify that all disks are in normal state, enter: showpd -s.
7. Enter: showpd and make note of the number of Physical Disks (PDs) in the system.
8. To check PDs status and firmware level, enter:
showpd -showcols Id,CagePos,Node_WWN,Manuf,FW_Rev,Serial,FW_Status
cli% showpd -showcols Id,CagePos,Node_WWN,Manuf,FW_Rev,Serial,FW_Status
Id CagePos Node_WWN Manuf FW_Rev Serial FW_Status
0 0:0:0 5000CCA0165D04CF HITACHI 3P00 KMHN4VXF current
1 0:1:0 5000CCA0165CD48B HITACHI 3P00 KMHN1N8F current
2 1:0:0 5000CCA016579EC3 HITACHI 3P00 KMHK5UNF current
3 1:1:0 5000CCA0165A6023 HITACHI 3P00 KMHLPTXF current
4 3:0:0 5000CCA0165856F3 HITACHI 3P00 KMHKL2XF current
5 3:1:0 5000CCA02231D803 HITACHI 3P00 KMVWDT7F current
6 4:0:0 5000CCA0165D60A3 HITACHI 3P00 KMHNAZHF current
7 4:1:0 5000CCA02231CFBF HITACHI 3P00 KMVWD75F current
8 5:0:0 5000CCA0165D31DB HITACHI 3P00 KMHN7VXF current
9 5:1:0 5000CCA0165B329B HITACHI 3P00 KMHM4UEF current
10 6:0:0 5000CCA0165D79B7 HITACHI 3P00 KMHNDN8F current
11 6:1:0 5000CCA0165D63A3 HITACHI 3P00 KMHNB5PF current
12 7:0:0 5000CCA0165D606B HITACHI 3P00 KMHNAZ1F current
13 7:1:0 5000CCA0165D609F HITACHI 3P00 KMHNAZGF current
14 2:0:0 5000CCA02231D0C3 HITACHI 3P00 KMVWD98F current
15 2:1:0 5000CCA0165D3A7F HITACHI 3P00 KMHN8ESF current
-------------------------------------------------------------
9. To check cage status and firmware, enter:
showcage d
10. Verify the health of the Storage System. For more information, see “Performing Check Health
(page 11).
6 Verification and Preparation