3PAR InForm® OS 2.3.1 MU3 Patch 16 Release Notes 3PAR Inc.
Revision Notice This is the first release of this document. Changes The material in this document is for information only and is subject to change without notice. While reasonable efforts have been made in the preparation of this document to assure its accuracy, 3PAR Inc. assumes no liability resulting from errors or omissions in this document or from the use of the information contained herein.
InForm OS Version 2.3.1 Release 2.3.1 MU3 P16 Release Notes These release notes are for Patch 16 (P16), which is intended for application to the 3PAR InForm OS 2.3.1.298 (MU3). 1.0 Supported Platforms The 3PAR Configuration Matrix for InForm OS 2.3.1 contains information about supported hardware and software platforms. Contact your local sales engineer or service representative to obtain a copy, or find it online at http://www.3par.com.
Release 2.3.1 MU3 P16 Release Notes 50428 InForm OS Version 2.3.1 The cimserver process A response queue function is serialized per request occasionally crashed when by locking a mutex owner by the sending chunked responses. OperationAggregate object for that request. Unfortunately, if the response queued is the last response, the OperationAggregate object is deleted within the method.
InForm OS Version 2.3.1 58426 Release 2.3.1 MU3 P16 Release Notes Issuing Fixed a problem where the ModifyInstance TPD_StorageHardwareID operation on TPD_StorageHardwareIDCollection to Collectionmodifyinstance change the HostPersonaID results in an error. returned an error code.
Release 2.3.1 MU3 P16 Release Notes InForm OS Version 2.3.1 4.0 Known Issues The following items are known issues with this release. Bug ID Item Workaround 45498 CIM failed with “Volume When creating a persistent StorageSetting leave the size cannot be greater than TemplateVolumeSize property NULL. Then when 16TB when creating a VV creating a volume, specify the volume size in the Size template with the parameter of the TemplateVolumeSize set to CreateOrModifyElementFromStoragePool method.
InForm OS Version 2.3.1 Release 2.3.1 MU3 P16 Release Notes Bug ID Item Workaround 55445 Querying a volume with a The VV buffer in the apilib is 1 byte shorter when it 31 character-long name should be 32 bytes including a 1 null terminator. A 31 results in cimserver and bytes long VV name caused the cimserver to crash. Set system manager crashes. the VV ames to 30 characters or shorter. If the existing volume already has a name that is 31 characters long, use setvv -name vvname to rename it.
Release 2.3.1 MU3 P16 Release Notes 8 InForm OS Version 2.3.