3PAR InForm® OS 2.3.1 Messages and Operator's Guide (320-200181 Rev B, February 2010)

12.96
Messages and Operator’s Guide InForm OS Version 2.3.1
Check if the cables are properly seated. Confirm the loop is off line by running CLI command
showpd -degraded and showpd -failed.
STATE 9
Single ESI Port
SUGGESTED ACTION
The cage has only one ESI PD online. A disk in the ESI position may be off line. Use the CLI
command showpd -p -cg <cage_name> to verify if any disks are off line. If a PD is off-line
due to a Servicemag operation or other service operation, the alert will auto resolve. Contact
your local service provider for technical support and services.
Validate the alert by running CLI command showpd -degraded and showpd -failed. If ESI
PDs are intentionally off line, reconnect them. Replace PDs if they are failing.