3PAR InForm® OS 2.3.1 Messages and Operator's Guide (320-200181 Rev B, February 2010)

12.89
InForm OS Version 2.3.1 Messages and Operator’s Guide
SUGGESTED ACTION
Power supply failed to initialize. Replace Power Supply.
MESSAGE 41
POST Power Supply Probe <error> <code>.
SUGGESTED ACTION
Power supply failed during functional test. Replace Power Supply.
MESSAGE 42
POST Power Supply EEPROM Test <error> <code>.
SUGGESTED ACTION
Power supply EEPROM failed during functional test. Replace Power Supply.
MESSAGE 43
POST Power Supply Test <error> <code>.
SUGGESTED ACTION
Power supply failed during functional test. Replace Power Supply.
MESSAGE 44
POST ESI Test <error> <code>.
SUGGESTED ACTION
Internal midplane hardware error. ESI channel failed to initialize. Replace midplane.
MESSAGE 45
POST ESI Init <error> <code>.
SUGGESTED ACTION
Internal midplane hardware error. ESI channel failed to initialize. Replace midplane.
MESSAGE 46
POST PMC Alive Test <error> <code>.
SUGGESTED ACTION
Internal midplane hardware error. ESI channel failed to initialize. Replace midplane.