3PAR InForm® OS 2.3.1 Messages and Operator's Guide (320-200181 Rev B, February 2010)

11.22
Troubleshooting InServ Storage Server Components
Messages and Operator’s Guide InForm OS Version 2.3.1
Examine the date of the last successful test of that battery. Assuming the comment date was
2009-10-14, the last battery test on
Node 0, PS 1, Bat 0 was 2009-09-10, which is more
than 30 days in the past.
showbattery -log
Node PS Bat Test Result Dur(mins) ---------Time----------
0 0 0 0 Passed 1 2009-10-14 14:34:50 PDT
0 0 0 1 Passed 1 2009-10-28 14:36:57 PDT
0 1 0 0 Passed 1 2009-08-27 06:17:44 PDT
0 1 0 1 Passed 1 2009-09-10 06:19:34 PDT
showbattery
Node PS Bat Serial -State-- ChrgLvl(%) -ExpDate-- Expired Testing
0 0 0 83205243 OK 100 04/07/2011 No No
0 1 0 83202356 Degraded 100 04/07/2011 No No
11.4.8 PD
Displays Physical Disks (PDs) with states or conditions that are not optimal.
Checks for failed and degraded PDs
Checks for an imbalance of PD ports, for example, if Port-A is used on more disks than Port-
B.
Checks for an "Unknown" Sparing Algorithm. For example, when it hasn't been set
Checks for disks experiencing a high number of IOPS
Reports if a servicemag operation is outstanding (servicemag status)
11.4.8.1 Format of Possible PD Exception Messages
PD disk:<pdid> "Detailed State: <showpd -s -degraded -failed">
PD -- "There is an imbalance of active PD ports"
PD -- "Sparing algorithm is not set"
PD disk:<pdid> "Disk is experiencing a high level of I/O per second: <iops>"
PD -- There is at least one active servicemag operation in progress
11.4.8.2 PD Example 1
Component -------------------Description------------------- Qty
PD PDs that are degraded or failed 40
Component -Identifier- ---------------Description-----------------
PD disk:48 Detailed State: missing_B_port,loop_failure
PD disk:49 Detailed State: missing_B_port,loop_failure
...