3PAR InForm® OS 2.3.1 Messages and Operator's Guide (320-200181 Rev B, February 2010)
11.21
Troubleshooting InServ Storage Server Components
InForm OS Version 2.3.1 Messages and Operator’s Guide
Node --Name--- -State-- Master InCluster ---LED--- Mem(MB) Mem(MB) Available(%)
2 1001356-2 OK No Yes GreenBlnk 2048 8192 100
3 1001356-3 Degraded No Yes AmberBlnk 2048 8192 100
cli% shownode -s
Node -State-- -Detailed_State-
2 OK OK
3 Degraded PS 1 Degraded
cli% shownode -ps
Node PS -Serial- -PSState- FanState ACState DCState -BatState- ChrgLvl(%)
2 0 FFFFFFFF OK OK OK OK OK 100
2 1 FFFFFFFF OK OK OK OK OK 100
3 0 FFFFFFFF OK OK OK OK OK 100
3 1 FFFFFFFF Degraded OK OK OK Failed 0
cli% showbattery
Node PS Bat Serial -State-- ChrgLvl(%) -ExpDate-- Expired Testing
3 0 0 100A300B OK 100 07/01/2011 No No
3 1 0 12345310 Failed 0 04/07/2011 No No
11.4.7.7 Node Example 3
Component -Identifier- --------------Description----------------
Node node:3 Node:3, Power Supply:1, Battery:0 has not been tested
within the last 30 days
11.4.7.8 Node Suggested Action 3
The indicated battery has not been tested in the past 30 days. A node backup battery will be
tested every 14 days under normal conditions, but if a battery is missing, expired, or failed, it
will not be tested. In addition, the other battery connected to the same node will not be tested
because testing it would cause loss of battery backup to the node, and the system will not
allow that. An untested battery will have an Unknown status in the
showbattery -s output.
Use commands such as showbattery, showbattery -s, showbattery -d, and
showbattery -log.
showbattery -s
Node PS Bat -State-- -Detailed_State-
0 0 0 OK normal
0 1 0 Degraded Unknown