3PAR InForm® OS 2.3.1 Messages and Operator's Guide (320-200181 Rev B, February 2010)

11.11
Troubleshooting InServ Storage Server Components
InForm OS Version 2.3.1 Messages and Operator’s Guide
cli% showcage -d cage3
Id Name LoopA Pos.A LoopB Pos.B Drives Temp RevA RevB Model Side
3 cage3 2:0:4 0 3:0:4 0 32 29-41 2.36 2.36 DC2 n/a
-----------Cage detail info for cage3 ---------
.
.
.
-----------Midplane Info-----------
Firmware_status Old
Product_Rev 2.36
State Normal Op
Loop_Split 0
VendorId,ProductId 3PARdata,DC2
Unique_ID 10320300000AD100
cli% showfirmwaredb
Vendor Prod_rev Dev_Id Fw_status Cage_type Firmware_File
...
3PARDATA [2.37] DC2 Current DC2 /opt...dc2/lbod_fw.bin-2.37
11.4.2.10 Cage Example 5
Component -Identifier- ------------Description------------
Cage cage:4 Interface Card 0, SFP 0 is unqualified
11.4.2.11 Cage Suggested Action 5
In this example, a 2Gb/sec SFP was installed in a 4Gb/sec drive cage (DC4), and the 2Gb SFP is
not qualified for use in this drive cage. For cage problems, the following CLI commands are
helpful:
showcage -d, showcage -sfp, showcage -sfp -ddm, showcage -sfp -d, and
showpd -state.
cli% showcage -d cage4
Id Name LoopA Pos.A LoopB Pos.B Drives Temp RevA RevB Model Side
4 cage4 2:2:1 0 3:2:1 0 8 30-37 2.37 2.37 DC4 n/a
-----------Cage detail info for cage4 ---------
Fibre Channel Info PortA0 PortB0 PortA1 PortB1
Link_Speed 2Gbps -- -- 4Gbps
----------------------------------SFP Info-----------------------------------
FCAL SFP -State- --Manufacturer-- MaxSpeed(Gbps) TXDisable TXFault RXLoss DDM
0 0 OK SIGMA-LINKS 2.1 No No No Yes
1 1 OK FINISAR CORP. 4.1 No No No Yes