3PAR InForm® OS 2.3.1 Messages and Operator's Guide (320-200181 Rev B, February 2010)

11.10
Troubleshooting InServ Storage Server Components
Messages and Operator’s Guide InForm OS Version 2.3.1
Product_Rev 2.37
State Normal Op
Loop_Split 0
VendorId,ProductId 3PARdata,DC2
Unique_ID 10320300000AD000
cli% showpd -s
Id CagePos Type -State-- -----Detailed_State------
20 1:0:0 FC degraded disabled_B_port,servicing
21 1:0:1 FC degraded disabled_B_port,servicing
22 1:0:2 FC degraded disabled_B_port,servicing
23 1:0:3 FC degraded disabled_B_port,servicing
cli% showpd -p -cg 1
---Size(MB)---- ----Ports----
Id CagePos Type Speed(K) State Total Free A B
20 1:0:0 FC 10 degraded 139520 119808 0:0:2* 1:0:2-
21 1:0:1 FC 10 degraded 139520 122112 0:0:2* 1:0:2-
22 1:0:2 FC 10 degraded 139520 119552 0:0:2* 1:0:2-
23 1:0:3 FC 10 degraded 139520 122368 0:0:2* 1:0:2-
11.4.2.8 Cage Example 4
SComponent ---------Description--------- Qty
Cage Cages not on current firmware 1
Component -Identifier- ------Description------
Cage cage:3 Firmware is not current
11.4.2.9 Cage Suggested Action 4
Check the drive cage firmware revision using the command showcage and showcage -d
cageX
. The showfirwaredb command indicates what the current firmware level should be
for the specific drive cage type.
cli% showcage
Id Name LoopA Pos.A LoopB Pos.B Drives Temp RevA RevB Model Side
2 cage2 2:0:3 0 3:0:3 0 24 29-43 2.37 2.37 DC2 n/a
3 cage3 2:0:4 0 3:0:4 0 32 29-41 2.36 2.36 DC2 n/a
NOTE: DC1 and DC3 cages have firmware in the FCAL-Modules; DC2 and DC4
cages have firmware on the cage midplane. The
upgradecage command may be
used to upgrade the firmware.