3PAR InForm® OS 2.3.1 Messages and Operator's Guide (320-200181 Rev B, February 2010)

11.7
Troubleshooting InServ Storage Server Components
InForm OS Version 2.3.1 Messages and Operator’s Guide
----------------------------------SFP Info-----------------------------------
FCAL SFP -State- --Manufacturer-- MaxSpeed(Gbps) TXDisable TXFault RXLoss DDM
0 0 OK FINISAR CORP. 4.1 No No Yes Yes
1 1 OK FINISAR CORP. 4.1 No No No Yes
Interface Board Info FCAL0 FCAL1
Link A RXLEDs Off Off
Link A TXLEDs Green Off
Link B RXLEDs Off Green
Link B TXLEDs Off Green
LED(Loop_Split) Off Off
LEDS(system,hotplug) Green,Off Green,Off
-----------Midplane Info-----------
Firmware_status Current
Product_Rev 2.37
State Normal Op
Loop_Split 0
VendorId,ProductId 3PARdata,DC4
Unique_ID 1062030000098E00
...
-------------Drive Info------------- ----LoopA----- ----LoopB-----
Drive NodeWWN LED Temp(C) ALPA LoopState ALPA LoopState
0:0 2000001d38c0c613 Green 33 0xe1 Loop fail 0xe1 OK
0:1 2000001862953510 Green 35 0xe0 Loop fail 0xe0 OK
0:2 2000001862953303 Green 35 0xdc Loop fail 0xdc OK
0:3 2000001862953888 Green 31 0xda Loop fail 0xda OK
cli% showcage -sfp cage4
Cage FCAL SFP -State- --Manufacturer-- MaxSpeed(Gbps) TXDisable TXFault RXLoss DDM
4 0 0 OK FINISAR CORP. 4.1 No No Yes Yes
4 1 1 OK FINISAR CORP. 4.1 No No No Yes
cli% showcage -sfp -ddm cage4
---------Cage 4 Fcal 0 SFP 0 DDM----------
-Warning- --Alarm--
--Type-- Units Reading Low High Low High
Temp C 33 -20 90 -25 95
Voltage mV 3147 2900 3700 2700 3900
TX Bias mA 7 2 14 1 17
TX Power uW 394 79 631 67 631