Troubleshooting InServ Storage Server Components
Messages and Operator’s Guide InForm OS Version 2.3.1
SFP signal levels (RX power low and TX failure)
power supplies
cage firmware (is not current)
Reports if a
servicecage operation has been started and has not ended.
11.4.2.1 Format of Possible Cage Exception Messages
Cage cage:<cageid> "Missing A loop" (or "Missing B loop")
Cage cage:<cageid> "Interface Card <STATE>"
Cage cage:<cageid>,mag:<magpos> "Magazine is <MAGSTATE>"
Cage cage:<cageid> "Power supply <X> fan is <FANSTATE>"
Cage cage:<cageid> "Power supply <X> is <PSSTATE>" (Degraded, Failed,
Not_Present)
Cage cage:<cageid> "Power supply <X> AC state is <PSSTATE>"
Cage cage:<cageid> "Cage has a hotplug enabled interface card"
Cage cage:<cageid> "Firmware is not current"
11.4.2.2 Cage Example 1
Component -------------Description-------------- Qty
Cage Cages missing A loop 1
Cage SFPs with low receiver power 1
Component -Identifier- --------Description------------------------
Cage cage:4 Missing A loop
Cage cage:4 Interface Card 0, SFP 0: Receiver Power Low: Check FC Cable
11.4.2.3 Cage Suggested Action 1
Check the connection/path to the SFP in the cage and the level of signal the SFP is receiving. An
RX Power reading below 100 uW will signal the RX Power Low condition; typical readings are
between 300 and 400 uW. Helpful CLI commands are
showcage -d and showcage -sfp
ddm
.
At least two connections are expected for drive cages and this exception will be flagged if that
is not the case.
cli% showcage -d cage4
Id Name LoopA Pos.A LoopB Pos.B Drives Temp RevA RevB Model Side
4 cage4 --- 0 3:2:1 0 8 28-36 2.37 2.37 DC4 n/a
-----------Cage detail info for cage4 ---------
Fibre Channel Info PortA0 PortB0 PortA1 PortB1
Link_Speed 0Gbps -- -- 4Gbps