3PAR InForm® OS 2.3.1 Messages and Operator's Guide (320-200181 Rev B, February 2010)
11.6
Troubleshooting InServ Storage Server Components
Messages and Operator’s Guide InForm OS Version 2.3.1
■ SFP signal levels (RX power low and TX failure)
■ power supplies
■ cage firmware (is not current)
Reports if a
servicecage operation has been started and has not ended.
11.4.2.1 Format of Possible Cage Exception Messages
Cage cage:<cageid> "Missing A loop" (or "Missing B loop")
Cage cage:<cageid> "Interface Card <STATE>"
Cage cage:<cageid>,mag:<magpos> "Magazine is <MAGSTATE>"
Cage cage:<cageid> "Power supply <X> fan is <FANSTATE>"
Cage cage:<cageid> "Power supply <X> is <PSSTATE>" (Degraded, Failed,
Not_Present)
Cage cage:<cageid> "Power supply <X> AC state is <PSSTATE>"
Cage cage:<cageid> "Cage has a hotplug enabled interface card"
Cage cage:<cageid> "Firmware is not current"
11.4.2.2 Cage Example 1
Component -------------Description-------------- Qty
Cage Cages missing A loop 1
Cage SFPs with low receiver power 1
Component -Identifier- --------Description------------------------
Cage cage:4 Missing A loop
Cage cage:4 Interface Card 0, SFP 0: Receiver Power Low: Check FC Cable
11.4.2.3 Cage Suggested Action 1
Check the connection/path to the SFP in the cage and the level of signal the SFP is receiving. An
RX Power reading below 100 uW will signal the RX Power Low condition; typical readings are
between 300 and 400 uW. Helpful CLI commands are
showcage -d and showcage -sfp
ddm
.
At least two connections are expected for drive cages and this exception will be flagged if that
is not the case.
cli% showcage -d cage4
Id Name LoopA Pos.A LoopB Pos.B Drives Temp RevA RevB Model Side
4 cage4 --- 0 3:2:1 0 8 28-36 2.37 2.37 DC4 n/a
-----------Cage detail info for cage4 ---------
Fibre Channel Info PortA0 PortB0 PortA1 PortB1
Link_Speed 0Gbps -- -- 4Gbps