3PAR InForm® OS 2.3.1 Messages and Operator's Guide (320-200181 Rev B, February 2010)

8.8
Using the Component LEDs
Messages and Operator’s Guide InForm OS Version 2.3.1
System Fault
LED
Steady
amber light
Indicates the following:
Test state (5 seconds), if:
Power On LED is steady green.
Power Supply/Cooling/Temperature Fault LED is steady
amber.
Invalid Address LED is steady amber.
2 Gb Link Speed LED is steady amber.
Processor module in FCAL failure, if:
Power ON LED is steady green.
Power Supply/Cooling/Temperature Fault LED is off.
Unknown FCAL module type installed, 12C Bus failure, or
backplane autostart watchdog failure, if:
Power ON LED is steady green.
Power Supply/Cooling/Temperature Fault LED is off.
Ops to ESI communication failure, if:
Power ON LED is steady green.
Power Supply/Cooling/Temperature Fault LED is flashing.
Flashing
amber light
Indicates the following:
Over or under temperature, if:
Power On LED is steady green.
Power Supply/Cooling/Temperature Fault LED is steady
amber.
Power supply is removed and system power redundancy check
option is set, if:
Power On LED is steady green.
Power Supply/Cooling/Temperature Fault LED is flashing.
No drives fitted, if:
Power ON LED is steady green.
Power Supply/Cooling/Temperature Fault LED is off.
Table 8-2. Drive Chassis OPs Panel LED Meanings (continued)
LED Appearance Meaning