3PAR InForm® OS 2.3.1 CLI Reference (320-200166 Rev B, March 2010)

30.3
InForm OS Version 2.3.1 Command Line Interface Reference
–file <fpname>
Use firmware in file <fpname>, where <fpname> is the full path name of the file on the
node. The default is to use the firmware that is marked current in the firmware database
(see the
showfirmwaredb command).
–minlevel <revlevel>
Minimum firmware level that the cage firmware must be at for the upgrade to be allowed.
This option is deprecated and will be removed in a future release.
–maxlevel <revlevel>
Maximum firmware level that the cage firmware must be at for the upgrade to be allowed.
This option is deprecated and will be removed in a future release.
SPECIFIERS
<cagename>
Specifies the name displayed in the Name column using the showcage command.
RESTRICTIONS
Access to all domains is required to run this command.
EXAMPLES
The following example displays a cage with firmware level of 4.41 upgrading to 4.42:
NOTES
Before executing the upgradecage command, issue the showcage command to obtain
the names of the drive cages in the system.
When the upgradecage command is issued, the drive cage becomes temporarily
unavailable. The cage automatically restarts following the firmware update, and may
briefly disrupt the loops during the restart. It is recommended
showcage be used
approximately one minute after the update completes to ensure both loops to the cage are
available again.
cli% upgradecage –a
Upgrading cage cage0 cpuA from rev 1.46 to revision in file /opt/tpd/fw/cage/dc2/lbod_fw.bin-2.05.
Upgrading cage cage1 cpuA from rev 1.46 to revision in file /opt/tpd/fw/cage/dc2/lbod_fw.bin-2.05.
Upgrading cage cage2 cpuA from rev 1.46 to revision in file /opt/tpd/fw/cage/dc2/lbod_fw.bin-2.05.
Upgrading cage cage3 cpuA from rev 03 to revision in file /opt/tpd/fw/cage/dc3/dc3_fw.bin-04.
Skipping cage cage4 cpuA already up to date at rev 2.05
Skipping cage cage5 cpuA & cpuB already up to date at rev 04