3PAR InForm® OS 2.3.1 CLI Reference (320-200166 Rev B, March 2010)
25.45
InForm OS Version 2.3.1 Command Line Interface Reference
maxs
Specifies that only devices with maximum values above the threshold are
displayed.
<op>
The <operation> argument can be specified with one of the following arguments:
r
Specifies that read-only statistics are displayed.
w
Specifies that write-only statistics are displayed.
t|rw
Specifies that statistics for read and write totals are displayed.
<meas>
The <meas> argument can be specified with one of the following arguments:
iops
Specifies that I/O operations per second are displayed. If this argument is
used, the minimum threshold value must be specified using the
<val>
argument.
bw
Specifies that statistics for bandwidth in bytes per second are displayed. If this
argument is used, the minimum threshold value must be specified using the
<val> argument.
svct
Specifies that statistics for service time in milliseconds are displayed.
size
Specifies that statistics for I/O operations in bytes are displayed.
<val> [k|K]|[m|M]|[g|G]
Specifies the minimum threshold using any integer. The integer can be optionally
followed with k or K to indicate a multiple of 1,000, m or M to indicate a multiple of
1,000,000, or
g or G to indicate a multiple of 1,000,000,000.
An example of this option in use is
–filt curs,r,iops,10k that indicates that statistics
for a device that has more than 10,000 current read-only I/O operations are displayed.