3PAR InFormĀ® OS 2.3.1 CLI Reference (320-200166 Rev B, March 2010)

25.27
InForm OS Version 2.3.1 Command Line Interface Reference
<type>
The type argument can be specified with one of the following arguments:
curs
Specifies that only devices with current statistics above the threshold are
displayed.
avgs
Specifies that only devices with average statistics above the threshold are
displayed.
maxs
Specifies that only devices with maximum values above the threshold are
displayed.
<op>
The operation argument can be specified with one of the following arguments:
r
Specifies that read-only statistics are displayed.
w
Specifies that write-only statistics are displayed.
t|rw
Specifies that statistics for read and write totals are displayed.
<meas>
The meas argument can be specified with one of the following arguments:
iops
Specifies that I/O operations per second are displayed. If this argument is
used, the minimum threshold value must be specified using the
val
argument.
bw
Specifies that statistics for bandwidth in bytes per second are displayed. If this
argument is used, the minimum threshold value must be specified using the
val argument.
svct
Specifies that statistics for service time in milliseconds are displayed.