3PAR InForm® OS 2.3.1 CLI Reference (320-200166 Rev B, March 2010)

22.124
Command Line Interface Reference InForm OS Version 2.3.1
loss_sync. The port is not physically connected to anything.
config_wait. Firmware has yet to be initialized.
login_wait. Fibre Channel adapter is attempting port and process logins with all loop
ports.
error. Fibre Channel adapter has experienced an unrecoverable error.
non_participate. Port is logically isolated from the Fibre Channel loop.
offline. The port is offline.
pending_reset. A reset of the port has been scheduled, but not yet completed.
Node_WWN. The WWN that belongs to the controller node identified in the N:S:P column.
Port_WWN/HW_Addr. The WWN that belongs to the controller node port identified in the
N:S:P
column.
Type. Indicates the port connection type.
host. Port is connected to hosts. This port can also be used for Remote Copy over IP
(RCIP).
disk. Port is connected to disks.
free. Port is not connected.
The following example displays hardware and connection information about the ports’ Fibre
Channel settings:
cli% showport -i
N:S:P Brand Model Rev Firmware Serial
1:2:1 3PAR FC044X 08 1.02.N.5 00981760001d6187
1:2:2 3PAR FC044X 08 1.02.N.5 00981760001d6187
1:2:3 3PAR FC044X 08 1.02.N.5 00981760001d6187
1:2:4 3PAR FC044X 08 1.02.N.5 00981760001d6187