Command Line Interface Reference InForm OS Version 2.3.1
◆ loss_sync. The port is not physically connected to anything.
◆ config_wait. Firmware has yet to be initialized.
◆ login_wait. Fibre Channel adapter is attempting port and process logins with all loop
ports.
◆ error. Fibre Channel adapter has experienced an unrecoverable error.
◆ non_participate. Port is logically isolated from the Fibre Channel loop.
◆ offline. The port is offline.
◆ pending_reset. A reset of the port has been scheduled, but not yet completed.
■ Node_WWN. The WWN that belongs to the controller node identified in the N:S:P column.
■ Port_WWN/HW_Addr. The WWN that belongs to the controller node port identified in the
N:S:P
column.
■ Type. Indicates the port connection type.
◆ host. Port is connected to hosts. This port can also be used for Remote Copy over IP
(RCIP).
◆ disk. Port is connected to disks.
◆ free. Port is not connected.
The following example displays hardware and connection information about the ports’ Fibre
Channel settings:
cli% showport -i
N:S:P Brand Model Rev Firmware Serial
1:2:1 3PAR FC044X 08 1.02.N.5 00981760001d6187
1:2:2 3PAR FC044X 08 1.02.N.5 00981760001d6187
1:2:3 3PAR FC044X 08 1.02.N.5 00981760001d6187
1:2:4 3PAR FC044X 08 1.02.N.5 00981760001d6187