cpu_vrm_overheating. The node CPU VRM overheating.
control_cache_dimm_overheating. The node Control Cache DIMM is overheating.
node_offline_due_to_failure. The node is offline due to failure.
node_shutdown_manually. The node was shutdown manually.
unknown. The node state is unknown.
The following example displays the detailed state of the power supplies:
In the example above:
Node. The node ID.
PS. The power supply ID.
State. The power supply state. Values are as follows:
OK. The power supply is operating normally.
Failed. The power supply is operating abnormally.
NotPresent. The power supply is missing.
Degraded. The fan failure or battery state is not OK.
Detailed_State. The power supply detailed state. Values are as follows:
invalid_bat_count. The power supply has an invalid battery count.
dc_failed. The power supply DC failed.
ac_failed. The power supply AC failed.
fan_failed. The power supply fan failed.
charger_overload. The power supply charger overloaded.
battery_not_present. The power supply battery is not present.
cli% shownode -ps -s
Node PS -State- -Detailed_State-
0 0 OK OK
1 1 OK OK
2 2 OK OK
3 3 OK OK