3PAR InForm® OS 2.3.1 CLI Reference (320-200166 Rev B, March 2010)
22.84
Command Line Interface Reference InForm OS Version 2.3.1
The following example displays the detailed state of the nodes:
In the example above:
■ Node. The node ID.
■ State. The state of the node. Values are as follows:
◆ OK. The node and its components are operating normally.
◆ Degraded. The node is degraded when the power supply is missing, failed, or degraded
(fan failed, battery max life low, failed, expired, or not present).
◆ Failed. The node is either not initialized, offline, kernel revision mismatched, disk
partition bad, rebooting, or shut down.
■ Detailed_State. The detailed state of the node. Values are as follows:
◆ tod_bat_fail. The time of day battery failed.
◆ invalid_bat_config. The battery has an invalid configuration.
◆ link_error. The node has a link error.
◆ uncorrectable_mem_error. The node has an uncorrectable memory error.
◆ multi_uncorrectable_mem_error. The node has multiple uncorrectable memory
error.
◆ correctable_mem_error. The node has a correctable memory error.
◆ internal_system_error. The node has an internal system error.
◆ hardware_watchdog_error. The node has a hardware watchdog error.
◆ pci_error. There is a PCI error in the node.
◆ driver_software_error. The node has a driver software error.
◆ cpu_overheating. The node CPU overheating.
cli% shownode -s
Node -State- -Detailed_State-
0 OK OK
1 OK OK
2 OK OK
3 OK OK