3PAR InForm® OS 2.3.1 CLI Reference (320-200166 Rev B, March 2010)
22.17
InForm OS Version 2.3.1 Command Line Interface Reference
COMMAND
showcage
DESCRIPTION
The showcage command displays information about drive cages.
SYNTAX
The syntax of the showcage command can be one of the following:
■ showcage [options] [-d] [<cagename>...]
■ showcage [-sfp [-d|-ddm]] [<cagename>...]
■ showcage -i [<cagename>...]
AUTHORITY
Super, Service, Edit, Browse
OPTIONS
–d
Specifies that more detailed information about the drive cage is displayed. If this option is
not used, then only summary information about the drive cages is displayed.
–e
Displays error information.
–c
Specifies to use cached information. This option displays information faster because the
cage does not need to be probed, however, some information might not be up-to-date
without that probe.
–sfp
Specifies information about the SFP(s) attached to a cage. Currently, additional SFP
information can only be displayed for DC2 and DC4 cages.
–ddm
Specifies the SFP DDM information. This option can only be used with the -sfp option and
cannot be used with the
-d option.