3PAR InForm® OS 2.3.1 CLI Reference (320-200166 Rev B, March 2010)
22.5
InForm OS Version 2.3.1 Command Line Interface Reference
-wide
Do not truncate the message text. Only valid if the -oneline option is also specified.
SPECIFIERS
None.
RESTRICTIONS
Without any options, the showalert command displays all alerts in the New state.
EXAMPLES
The following example displays new alerts on a system:
NOTES
■ Set the status of alerts by issuing the setalert command. See setalert on page 21.3 for
more information.
■ Alerts can be removed by issuing the removealert command. See removealert on
page 19.3 for more information.
cli% showalert -n
Id : 1
State : New
Message Code: 0x2200de
Time : 2008-07-17 20:14:29 PDT
Severity : Degraded
Type : Component state change
Message : Node 0, Power Supply 1, Battery 0 Degraded (Unknown)
Id : 2
State : New
Message Code: 0xe000c
Time : 2008-07-17 20:15:31 PDT
Severity : Informational
Type : Cluster shutdown after system recovery completion
Message : System recovery completed for node 0 (reason Power Loss)
2 alerts